background image

www.gardcolighting.com

page

06/28/2021

1

443561208870 REV F

CSFS / CSFM

IMPORTANT: 

FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR 

ENTIRETY PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, 
PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional 
information is desired, please contact Signify, Lumec. [email protected] phone 1-833-744-6439. 

ClearScape Architecture Flood

443561208870 - CLEARSCAPE MAIN

Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local 
laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any hazards 
involved. If not qualified, do not attempt installation, service or maintenance.

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read 

all warnings and instructions included with the luminaire, on the luminaire’s packaging and affixed to the luminaire itself.

Maintenance of the luminaires should be performed by person(s) familiar with the luminaire’s construction and operation and a

ny hazards involved.

WARNING 
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY 

Disconnect or turn off power before attempting any installation, service or 
maintenance. 

Verify that supply voltage is correct by referencing the luminaire label 
information. 

Make all electrical and ground connections in accordance with the National 
Electrical Code (NEC) and any other applicable laws, regulations or codes.

All wiring connections should be capped with UL-approved wire connectors. 

WARNING 
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY 

Wear gloves and safety glasses at all times when removing luminaire 
from carton, installing, servicing or performing maintenance.

Avoid direct eye exposure to the light source while it is on. 

CAUTION 
RISK OF PRODUCT DAMAGE 

• Never connect luminaires and/or components under load with supply voltage turned on. 
• Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. 
• Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insu

lation, foam or other material that will 

prevent convection or conduction cooling. 

• Do not 

exceed luminaire maximum ambient temperature. 

• Do not modify the luminaire. 
• Only use luminaire in its intended application and location. 
• Led products are polarity sensitive. Ensure proper polarity before installation. 
• Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servici

ng of the luminaire. 

• Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance. 
• Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop

using it immediately and contact 

Signify. 

• Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific w

arnings. 

• In the case of HID or Fluorescent luminaires, regular re

-lamping is required to keep luminaire operating within safe limits 

• 

Do not install damaged product. 

Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts 

upon arrival of the luminaire.

• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency

to meet in connection with installation, 

operation or maintenance. 

• Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or reg

ulatory statements. Failure to follow 

any of these Instructions could void luminaires warranties. 

Luminaire Maintenance 

• Regular luminaire maintenance programs are 

recommended. 

• It is recommended to clean the outside of the luminaire and the refractor/lens. 
• Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. 
• If clean water is not sufficient for cleaning, use a neutral, synthetic, not

-scratching and not-abrasive cleaning substance. 

• Never use alkaline and/or acetous cleaning substances. 
• Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water. 
• Signify recommends using a cleaning solution that has a PH between 5 and 8. 
• Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov. 

WARNING 
RISK OF FIRE OR PERSONAL INJURY 

Keep combustible materials away from LED/lamp & lens

Do not operate in close proximity to persons, combustible materials 

or substances affected by heat or drying.

WARNING 
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY 

Allow Led/lamp & lens to cool before handling.

Do not touch enclosure or light source

Do not exceed maximum wattage marked on luminaire label.

Follow all manufacturer’s warnings, recommendations, instructions 

and restrictions for driver type, burning position, mounting locations 
and replacement.

1

Summary of Contents for Gardco CSFM

Page 1: ... modify the luminaire Only use luminaire in its intended application and location Led products are polarity sensitive Ensure proper polarity before installation Electrostatic Discharge ESD can damage LED Personal grounding equipment must be worn during all installation and servicing of the luminaire Do not touch individual electrical components as this can cause ESD shorten LED life or impact LED ...

Page 2: ...ositive lead to the supply dimming positive lead If Dimming is an option connect the grey dimming negative lead to the supply dimming negative lead SF Slip Fitter Mount Note Tenon must be 3 75 or longer 2 Splice Cover Screws Splice Cover Screws STEP 1 Remove 2 splice cover screws and splice cover To access wire splice area STEP 2 Route the supply wire through the tenon Secure the supply wire to ke...

Page 3: ...ete replace splice cover and 2 screws removed in Step 1 Ensure that gasket is correctly in place before tightening splice cover and screws SF Slip Fitter Angle Adjustment ANGLE ADJUSTMENT NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the angle of the luminaire can be adjusted approximately 90 up or down in 5 increments STEP 2 To adjust the ...

Page 4: ...llation is finished STEP 4 Replace junction box gasket and cover YK Yoke Angle Adjustment NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the vertical angle of the luminaire can be adjusted up or down STEP 2 To adjust the angle loosen the 2 1 2 13 X 1 25 socket head cap bolts located in yoke arm Do remove bolts Loosen only enough to allow rot...

Page 5: ...e glass to install luminaire STEP 1 Unfasten the captive shoulder screw around the glass perimeter excluding the bottom left safety screw STEP 2 Collect all screws and remove glass gently Be sure that gasket is still seated on rib Safety cable should remain attached while servicing luminaire STEP 3 After servicing luminaire carefully rotate glass door frame up into closed position and retighten sc...

Page 6: ...de mise à la terre pendant toute intervention d installation ou de réparation sur le luminaire Ne touchez pas aux composants électriques individuels étant donné que ceci peut causer une DES raccourcir la durée de vie des DEL ou nuire à leur rendement Certains composants internes du luminaire peuvent ne pas être réparables Aussi peu probable que ça pourrait l être si votre luminaire a besoin de rép...

Page 7: ... de gradation d alimentation 2 Vis de couverture d épissure SF Support de montage coulissant Remarque Le tenon doit mesurer 3 75 ou plus SF Support de montage coulissant Remarque Le tenon doit mesurer 3 75 ou plus ÉTAPE 1 Retirez les 2 vis du couvercle d épissure et le couvercle d épissure Pour accéder à la zone d épissure de fil ÉTAPE 2 Acheminez le fil d alimentation à travers le tenon Fixez le ...

Page 8: ...rcle d épissure et les 2 vis retirées à l étape 1 Assurez vous que le joint est correctement en place avant de serrer le couvercle d épissure et les vis RÉGLAGE DE L ANGLE REMARQUE Le réglage de l angle peut être effectué avant l installation du luminaire ÉTAPE 1 Une fois le luminaire installé l angle du luminaire peut être ajusté d environ 90 vers le haut ou vers le bas par incréments de 5 ÉTAPE ...

Page 9: ... Remettez le joint et le couvercle de la boîte de jonction YK Support de joug REMARQUE Le réglage de l angle peut être effectué avant l installation du luminaire ÉTAPE 1 Une fois le luminaire installé l angle vertical du luminaire peut être ajusté vers le haut ou vers le bas ÉTAPE 2 Pour régler l angle desserrez les 2 boulons à tête creuse 1 2 13 X 1 25 situés dans le bras de la fourche Retirez le...

Page 10: ...r étrier Il n est pas nécessaire d enlever le verre pour installer le luminaire ÉTAPE 1 Dévissez la vis à épaulement imperdable autour du périmètre du verre à l exception de la vis de sécurité en bas à gauche ÉTAPE 2 Récupérez toutes les vis et retirez délicatement le verre Assurez vous que le joint est toujours en place sur la nervure Le câble de sécurité doit rester attaché pendant l entretien d...

Reviews: