‡ SIGNET
8550-1 Flow Transmitter
CAUTION!
•
Remove power to unit before wiring
input and output connections.
•
Follow instructions carefully to avoid
personal injury.
‡ SIGNET
8550-1 Flow Transmitter
ENGLISH
Contents
1. Installation
2. Specifications
3. Electrical Connections
4. Menu Functions
•
Max loop impedance:
50
Ω
max. @ 12 V
325
Ω
max. @ 18 V
600
Ω
max. @ 24V
•
Update rate: 100 ms
•
Accuracy:
±
0.03 mA
Open-collector output, optically isolated:
•
50 mA max. sink, 30 VDC maximum pull-up voltage.
•
Programmable for:
•
High or Low setpoint with adjustable hysteresis
•
Pulse operation (max rate: 300 pulses/min).
Environmental
•
Operating temperature: -10 to 70
°
C (14 to 158
°
F)
•
Storage temperature:
-15 to 80
°
C (5 to 176
°
F)
•
Relative humidity:
0 to 95%, non-condensing
•
Maximum altitude:
2000 m (6562 ft)
•
Insulation category:
II
•
Pollution degree:
2
Standards and Approvals
•
CSA, CE, UL listed
•
Immunity:
EN50082-2
•
Emissions:
EN55011
•
Safety:
EN61010
•
Manufactured under ISO 9001 and ISO 14001
2 . Specifications
General
Compatibility: +GF+ SIGNET Flow Sensors (w/freq out)
Accuracy:
±
0.5 Hz
Enclosure:
•
Rating:
NEMA 4X/IP65 front
•
Case:
PBT
•
Panel case gasket:
Neoprene
•
Window:
Polyurethane coated polycarbonate
•
Keypad:
Sealed 4-key silicone rubber
•
Weight:
Approx. 325g (12 oz.)
Display:
•
Alphanumeric 2 x 16 LCD
•
Update rate: 1 second
•
Contrast: User selected, 5 levels
Electrical
•
Power: 12 to 24 VDC
±
10%, regulated, 61 mA max current
Sensor Input:
•
Range: 0.5 to 1500 Hz
•
Sensor power:
2-wire: 1.5 mA @ 5 VDC
±
1%
3 or 4 wire: 20 mA @ 5 VDC
±
1%
•
Optically isolated from current loop
•
Short circuit protected
Current output:
•
4 to 20 mA, isolated, fully adjustable and reversible
Flow
Flow 6.25 GPM
Total 1234567.8>
ENTER
3-8550.090-1
1.
Installation
ProcessPro transmitters are available in two styles: panel mount and field mount. The panel mount is supplied with the necessary
hardware to install the transmitter. This manual includes complete panel mounting instructions.
Field mounting requires one of two separate mounting kits. The 3-8051 integral kit joins the sensor and instrument together into a
single package. The 3-8050 Universal kit enables the transmitter to be installed virtually anywhere.
Detailed instructions for integral mounting or other field installation options are included with the 3-8051 Integral kit or the 3-8050
Universal kit.
1.1 Panel Installation
1.
The panel mount transmitter is designed for installation using a 1/4 DIN Punch. For manual panel cutout, an adhesive
template is provided as an installation guide. Recommended clearance on all sides between instruments is 1 inch.
2.
Place gasket on instrument, and install in panel.
3.
Slide mounting bracket over back of instrument until quick-clips snap into latches on side of instrument.
4.
To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE.
Press quick-clips outward and remove.
SIDE VIEW
92 mm
(3.6 in.)
97 mm
(3.8 in.)
56 mm
(2.2 in.)
41 mm
(1.6 in.
)
Optional
Rear
Cover
Field Mount
Panel Mount
FRONT VIEW
96 mm
(3.8 in.)
96 mm
(3.8 in.)
102 mm
(4.0 in.)
96 mm
(3.8 in.)
quick-clips
gasket
panel
terminals
mounting
bracket
latch
Out
put
-
Out
put
+
Sys
tem
Pw
r
Loo
p -
Sys
tem
Pw
r
Loo
p +
2
1
4
3
Sen
sr G
nd
(SH
IELD
)
Sen
sr IN
(RE
D)
Sen
sr V
+
(BLA
CK)
7
6
5
SIDE VIEW
Field Mount &
Panel Mount
Panel Mount
Installation Detail
C-3/01 English