background image

Safety Instructions

  1.  Prior to installation or removal:

•  Depressurize and vent system
•  Drain below sensor level 

 2.  Con

fi

 rm chemical compatibility before use.

  3.  Do not exceed maximum temperature/pressure speci

fi

 cations.

  4.  Wear safety goggles or faceshield during installation/service.
  5.  Do not alter product construction.
  6.  Dispose of properly; DO NOT INCINERATE!

Signet 2350 Temperature Sensor

1. Description

The Signet 2350 Temperature Sensor has a one-piece injection molded PVDF body that is ideal for use in high purity applications. It 
also outlasts metal sensors in aggressive liquids and eliminates the need for costly custom thermowells. These sensors are available 
with Digital (S

3

L) or 

fi

 eld-scaleable 4 to 20 mA output. Dual threaded ends (

3

/

4

 in. NPT) allow submersion in process vessels, or in-line 

installation with conduit connection. Integral adapters (sold separately) may be used to create a compact assembly with 

fi

 eld mount 

versions of the 8350 Temperature Transmitter.

2. Specifi cations

Dimensions

General

Compatibility: 

 

Signet 8350 Temperature Transmitters

     

 

 

Signet 8900 Multi-Parameter Controller

     

 

Signet 

9900 

Transmitter

Wetted material:   

PVDF

Measurement range:
• In-line installation: 

-10 °C to 100 °C (14 °F to 212 °F)

•  Submersible installation:  -10 °C to 85 °C (14 °F to 185 °F)
Response time, 

:  

10  seconds

Process connection: 

3

/

4

 in. NPT male thread

Rear connection: 

 

3

/

4

 in. NPT male thread

Cable type: 

 

3 cond + shield, 22 AWG

Standard cable length: 

4.6 m (15 ft)

Shipping weight:   

0.22 kg (0.5 lb)

Electrical

Power requirements:
• (S

3

L) models:   

5 VDC ±10%, <1.5 mA

• 4 to 20 mA models: 

12-24 VDC ±10%

Short circuit & reverse polarity protected
Digital (S

3

L) output: 

Serial ASCII, TTL level 9600 bps

• Accuracy: 

 

±0.5 °C (±0.9 °F)

• Repeatability:   

±0.1 °C (±0.2 °F)

• Resolution: 

 

0.01 °C (0.02 °F)

• Update rate: 

 

<100 ms

4 to 20 mA output:
• Accuracy: 

 

±32 

μ

A

•  Repeatability:   

±0.1 °C (±0.2 °F)

• Resolution: 

 

<5 

μ

A

•  Factory Span:    

0 °C to 100 °C, 

fi

 eld-scaleable.

•  Max loop impedance: 

  50 

Ω

 @ 12 V

 

 

 

 

  325 

Ω

 @ 18 V

 

 

 

 

  600 

Ω

 @ 24 V

•  Update rate: 

 

<100 ms

Environmental

•  Relative humidity: 

0  to 95% (Non-condensing)

•  Storage temperature: 

-55 °C to 100 °C (-67 °F to 212 °F)

Table of Contents

 1.  Description
 2.  Speci

fi

 cations

 3.  Installation
 4.  Digital (S

3

L) wiring

  5.  4 to 20 mA wiring
  6.  4 to 20 mA
  span 

adjustment

 7.  Ordering information

109 mm

 (4.27 in.)

82 mm

(3.22 in.)

¾ in. NPT 

30 mm

(1.18 in.)

Submersible installations
are limited to 85 °C (185 °F)

Application Limits

Pressure (bar)

Pressure (psi)

Temperature

3-2350.090-1  Rev. K   03/13     English

*3-2350.090-1*

English

Approvals & Standards

• CE
• RoHS Compliant
•  Manufactured under ISO 9001 for Quality, 

ISO 14001 for Environmental Management and 
OHSAS 18001 for Occupational Health and Safety.

  Declaration of Conformity according to FCC Part 15. 

This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and, 
(2) This device must accept any interference received, 
including interference that may cause undesired operation.

  China RoHS (Go to www.gfsignet.com for details)

Summary of Contents for 2350

Page 1: ... Cable type 3 cond shield 22 AWG Standard cable length 4 6 m 15 ft Shipping weight 0 22 kg 0 5 lb Electrical Power requirements S3 L models 5 VDC 10 1 5 mA 4 to 20 mA models 12 24 VDC 10 Short circuit reverse polarity protected Digital S3 L output Serial ASCII TTL level 9600 bps Accuracy 0 5 C 0 9 F Repeatability 0 1 C 0 2 F Resolution 0 01 C 0 02 F Update rate 100 ms 4 to 20 mA output Accuracy 32...

Page 2: ...the process connection Make sure the flow alignment indicator is in correct position in the pipe Damage to the sensor tip can occur if the sensor tip is installed improperly Install 8350 transmitter or 9900 refer to 8350 or 9900 manual for wiring information The 3 8052 Integral kit includes 3 4 in NPT process connection 3 9000 392 1 liquid tight connector 1 2 in NPT Conduit base to attach 8350 3 3...

Page 3: ...0 mA loop output when powered with 24 VDC Connecting the SHIELD to a direct Earth ground may reduce electrical noise interference Red wire is not used do not remove the heat shrink See Section 6 4 to 20 mA Span Adjustment 5 1 Current Loop With No Junction Box 5 2 Current Loop With Junction Box 3 8052 1 4 20 mA FREQ DATA WHT WHT BLU BLK N C RED SHIELD SENSOR INPUT SHIELD FREQ DATA White Black Power...

Page 4: ...signet com Or call in the U S 800 854 4090 For the most up to date information please refer to our website at www gfsignet com 3 2350 090 1 Rev K 03 13 English Georg Fischer Signet LLC 2013 WARNING Not protecting the red wire may cause the 4 to 20 mA span to be reset Wire Nut With power applied as described in Section 5 connect the RED wire to the WHITE wire for 15 seconds After about 10 seconds t...

Reviews: