Internal Adjustments
1 Chime
select
The 1ZPR contains an optional chime, which can be set to a 1, 2 or 3 note chime dependant on the jumper
settings, (this feature is not to be used with SigNET SS2n systems, as the chime is set with the SS2n).
No chime
(default)
1 note chime
2 note chime
3 note chime
2 Mic
monitoring
With the header in position the microphone
capsule is monitored, this is the default setting
and should
not
be removed for life safety
applications.
Removing the header disables mic monitoring
and subsequent fault indication on front panel.
3 EQ
controls
Bass, Mid and Treble controls are provided. Each
provides
12dB of attenuation. Turn fully clockwise for
max.
4
Master and Chime levels
Separate Audio and chime level controls are provided.
Turn fully clockwise for max.
Microphone Connection
Connect the microphone to the 1ZPR using the molex type connectors as per the following diagrams.
Standard Microphone
Microphone with external PTT
Page 3 of 4
DocNo.DCP0001372 ADS 14/11/05 rev4