Installation 

 

Unpacking 

Upon receipt of shipment, please inspect for any damage incurred in transit.  If damage is 

found, please notify your local representative and the transport company immediately.  State date, nature of 
damage and whether any damage was noticed on the shipping container prior to unpacking.  Please give the 
waybill number of the shipping order. 
The unit should not be placed in areas; 

with poor ventilation 

exposed to direct sunlight 

with high ambient temperature or adjacent to heat generating equipment 

with high humidity or dust levels 

susceptible to vibration 

Operation 

 
The 1ZPR has been designed to offer a simple microphone input to the network, with the choice of either local 
operation or global all call operation.  This function is selected on set up of the network system.  This unit can 
also be used in the SigNET LinX voice alarm systems. 
The microphone console comprises of a speak bar, VU Meter, and two status indicators, one for OK and one 
for fault. 
In order to page, the thumb switch on the microphone or the speak bar are pressed, and if the system is able 
to accept paging, the speak bar will light solid green and paging may commence. 
The speak bar LED indicator will flash if there is a busy input indicating that an equal or higher priority input to 
the system is in use on one of the selected zones, or that access to one of the selected zones is excluded.  If 
the zone selection is valid, the busy in will permit the speak bar to illuminate steadily and the announcement 
can be made. 

Fault monitoring 

 
The electret microphone capsule is monitored for impedance and current absorption.  Any deviation from pre-
set windows triggers the monitor circuit with the following results: 

1.  The OK LED is extinguished and the Fault LED illuminated. 
2.  The monitor circuit removes the 6K8 termination of the PTT.  This puts an open circuit condition on the 
     PTT line, signalling a fault to external control equipment. 

The audio lines are monitored by the phantom detect circuit which notifies any loss of the 15V phantom (due to 
an open circuit or short circuit line) to the monitor circuit.  The monitor circuit causes an open circuit condition 
to be set on the PTT, signalling a fault to signalling a fault to external control equipment. 

DC power operation 

 
The 1ZPR requires a 24V DC supply which enters the unit through the six core cabling (see 

page 4

). 

Caution 

This unit must never be directly connected into a 230V AC power supply

.

 

 

Page  2  of  4 

DocNo.DCP0001372  ADS  14/11/05  rev4 

Summary of Contents for 1ZPR

Page 1: ...ompression ratio The output of this stage is fed to an LED output level display and a three band equaliser 100 Hz 1KHz 10 kHz Power is supplied at nominal 24 VDC via separate cabling the phantom power on the audio and audio being used for fault detection only A regulator circuit provides 15 VDC for powering the 1ZPR electronics Front Panel Features The 1ZPR provides for the following LED indicatio...

Page 2: ... and paging may commence The speak bar LED indicator will flash if there is a busy input indicating that an equal or higher priority input to the system is in use on one of the selected zones or that access to one of the selected zones is excluded If the zone selection is valid the busy in will permit the speak bar to illuminate steadily and the announcement can be made Fault monitoring The electr...

Page 3: ...setting and should not be removed for life safety applications Removing the header disables mic monitoring and subsequent fault indication on front panel 3 EQ controls Bass Mid and Treble controls are provided Each provides 12dB of attenuation Turn fully clockwise for max 4 Master and Chime levels Separate Audio and chime level controls are provided Turn fully clockwise for max Microphone Connecti...

Page 4: ... of the 1ZPR pcb B D H G C A B A CAT5 connections are as follows A 24V B Gnd C PTT D Busy E F G Audio H Audio SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE SigNET AC Limited 6 Tower Road Glover Estate Washington Tyne Wear NE37 2SH Tel 0191 417 4551 Fax 0191 417 0634 Page 4 of 4 DocNo DCP0001372 ADS 14 11 05 rev4 ...

Reviews: