background image

RENATO RANGE HOOD INSTALLATION

REAR DISCHARGE

A 90-degree elbow may be installed immediately above the 

hood. 

CALCULATING VENT SYSTEM LENGTH

To calculate the length of the system you need, add the 

equivalent feet (meters) for all vent pieces used in the 

system. 

3

Renato Range Hood Installation Instructions

VENTILATION REQUIREMENTS 
(cont’d.)

Wood

Screws

INSTALLATION

TOOLS AND MATERIALS

Pencil

Level

Utility Knife

Drill

Tape Measure

Phillips 

Screwdriver

Duct Tape

6” Ducting

Outside Duct

Cap

Jigsaw

Drill holes A (W)-B-C according to indications quoted 
in (fig.1).

Use screws and screw anchors suitable for wall (e.g. 
reinforced cement, plasterboard) for the mounting of 

the range hood. Where screws and screw anchors are 
supplied, ensure that they are suitable for the type
of wall where the range hood is to be mounted.

Affix the bracket Z to the wall via the drill holes C.

Hang the range hood on the wall using the hooks A 
and bracket W.

Fasten the raange hood using the fastening drill holes 

B.

Connect the flange Y to the outside duct cap using 6” 
ducting. If the outside cap requires a 5” connection, a 
reduction coupling may be used (Fig.5).

Thread the upper flue cover E to the inside of the 
lower flue cover F. Hang the connected flue cover by 

inserting vertically on the range hood. Unthread the 

upper flue cover E towards the top, locking it in with 

the appropriate screws in the drill holes G of the 

bracket Z (fig. 7) whic was previously attached to the 

wall.

Summary of Contents for Renato

Page 1: ... vapors CAUTION To reduce the risk of fire and to properly exhaust air be sure to duct air outside DO NOT vent exhaust air into attics crawl spaces garages or within walls or ceilings 1 Renato Range Hood Installation Instructions TO REDUCE THE RISK OF A STOVETOP GREASE FIRE PLEASE READ THE FOLLOWING Never leave surface units unattended at high settings Boil over can cause smoke and grease to spill ...

Page 2: ...equirements VENTING METHOD To vent through a wall a 90 degree elbow is needed If exhaust ducting with a diameter less than 5 91 150mm or if flat ducting is used the noise level of the range hood could increase and extraction will be less efficient IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances specified on the model seri...

Page 3: ...cement plasterboard for the mounting of the range hood Where screws and screw anchors are supplied ensure that they are suitable for the type of wall where the range hood is to be mounted Affix the bracket Z to the wall via the drill holes C Hang the range hood on the wall using the hooks A and bracket W Fasten the raange hood using the fastening drill holes B Connect the flange Y to the outside duct...

Page 4: ...nato Range Hood Installation Instructions A B Fig 2 CONTROL PANEL 5 2 2 3 9 1 9 2 2 3 7 1 5 1 A 4 E P Y T 8 5 7 1 B 4 E P Y T _ 4 6 1 5 Z 0 2 2 3 3 1 1 3 4 6 7 3 5 9 32 B C Fig 1 Fig 3 EXHAUST MODE roof venting EXHAUST MODE wall venting ...

Page 5: ...RENATO RANGE HOOD INSTALLATION 5 Renato Range Hood Installation Instructions Ⓩ Ⓩ Ⓔ Ⓔ Ⓕ w w Ⓜ Ⓜ Fig 4_A Fig 4_B Ⓛ Ⓛ Fig 6 Fig 5 Ⓨ ...

Page 6: ...in pattern as this could impact the original finish Do not use chlorine bleach Grease Baffle Filter Remove the filter by pulling the spring release handle and then pulling down the filter Wash filters as needed in dishwasher or hot deter gent solution low temperature short cycle If your model contains a grease tray remove drain and clean periodically Make sure filters are completely dry before putting ba...