Signamax 065-7530/065-7540 Full-Duplex Switches
14
Installation
2
I
NSTALLATION
This chapter presents step-by-step installation
instructions for the Signamax 065-7530/065-7540
switches.
Selecting a Site for the Switch
As with any electronic device, you should place the
Signamax 065-7530/065-7540 switch where it will not be
subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you
select should meet the following requirements:
•
The room temperature should be between 32 and 104
degrees Fahrenheit (0 to 40 degrees Celsius).
•
The relative humidity should be less than 90 percent,
non-condensing.
•
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3,
Level 2 (3V/M) field strength.
•
Make sure that the switch receives adequate
ventilation. Do not block the ventilation holes on the
side of the switch or the fan exhaust port on the rear of
the switch. The power outlet should be within 1.8 Meter
of the switch.