Hardened Ethernet Switch
6
LED State
Indication
POWER
Steady
Switch is properly connected to power and
turned on.
PWR1
PWR2
(Green)
Off
Switch is not connected to power and is
turned off.
FAULT
Steady
1. Power failure occurred.
2. Port failure occurred (when port fault alarm
dip switch is enabled).
FAULT
(Red)
Off
1. Power failure is not occurred.
2. Port failure is not occurred (when port fault
alarm dip switch is enabled).
3. Port fault alarm dip switch is disabled.
10/100BaseT/TX
or
100BaseFX
Steady
A valid network connection established.
LNK stands for LINK.
LNK/ACT
(Green)
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady
Light solid yellow for a port transferring at
100Mbps.
100
(Yellow)
Off
The port is transferring at 10Mbps If this LED
is dark.
Assembly, Startup, and Dismantling
y
Assembly: Place the switch on the DIN rail from above
using the slot. Push the front of the switch toward the
mounting surface until it audibly snaps into place.
y
Startup: Connect the supply voltage to start up the
switch via the terminal block.
y
Dismantling: Pull out the lower edge and then remove
the switch from the DIN rail.