11
SignalFire Telemetry
Rev 1.6
Internal Lithium Battery Replacement
Battery Packs can be changed with the node in place.
1
Open the cover from the enclosure.
2
Unplug the battery from the PCB, by depressing the locking clip on the connector.
3
Loosen the screw holding the battery door and slide the old battery out.
4
Slide in the new battery pack and tighten the battery door screw.
5
Connect the battery to the main PCB battery connector.
6
Install the enclosure cover.
WARNING: Use of any battery other than the SignalFire part number 810-0008-02 will
impair the protection provided by the equipment.
WARNING: If the internal battery is installed the external solar battery system or other
power source may not be connected!
Cleaning Instructions
The outside of the enclosure may be cleaned with water, mild soap, and a damp cloth as needed. High pressure
washing is not recommended.
WARNING: Electrostatic Discharge Hazard! Care must be taken to avoid the potential of
creating a change on the enclosure or antenna. Do not wipe with a dry cloth. Do not brush
against the enclosure with clothing or gloves.