TAE 2144
BUILD-IN TOUCH TERMINAL
4 Technical Data
4.1 Performance Data
Interfaces
1x HMI Remote IN (HMI-Link G2.1)
2x USB 2.0 Type A OUT
1x Panel Interface Connector (for connecting a SIGMATEK TPs)
Internal interfaces
(via Panel Interface Connector)
USB 2.0 (for touch and front USB, if available on the TP)
Status LEDs
1x green
1x red (depends on OS)
Display
Resolution
21.5“ TFT color display
FullHD 1920 x 1080 pixels
Operating field
touch screen (projective capacitive)
Cooling
passive (fanless)
4.2 Electrical Requirements
Supply voltage
+24 V DC ±20 % (SELV/PELV)
UL: Class 2 or LVLC
(1)
Current consumption of (+24 V)
power supply
typically 1500 mA
(with no external devices
connected)
maximum 1700 mA
(with external devices connected)
Inrush current with 24 V/10 A
fixed voltage supply
maximum 3.1 A (for 17 ms, load-dependent)
Inrush current without current-
limiting supply
maximum 63 A (for 1.5 ms, load-dependent)
INFORMATION
(1)
For USA and Canada:
The supply must be limited to:
a) max. 5 A at voltages from 0-20 V DC, or
b) 100 W at voltages from 20-60 V DC
The limiting component (e.g. transformer, power supply or fuse) must be
certified by an NRTL (Nationally Recognized Testing Laboratory).
Page 12
09.09.2020