SPECIFICATION
:
Power:
Power:
Power:
Power:
Low power 5v DC mains
adaptor, 0.5W average
Dimensions:
Dimensions:
Dimensions:
Dimensions:
165mm x 66mm x 50mm
Installation:
Installation:
Installation:
Installation:
2 x No. 6 screws or adhesive pad
Media:
Media:
Media:
Media:
iButton™, Fingerprint, Mifare
Indicators:
Indicators:
Indicators:
Indicators:
4 digit numeric display
Two single-colour LED status
indicators, Audible buzzer
SIM card:
SIM card:
SIM card:
SIM card:
Easy-install caged SIM
connector
Cellular radio:
Cellular radio:
Cellular radio:
Cellular radio:
Quad GSM band
(800/900/1800/1900 MHz)
Cellular data:
Cellular data:
Cellular data:
Cellular data:
GPRS class 10 (packet)
RF connection:
RF connection:
RF connection:
RF connection:
Built-in dual-band antenna
(900/1800 MHz)
External antenna connection and
optional high-gain external antenna
Processing:
Processing:
Processing:
Processing:
104MHz, 32 bit ARM9 wireless
processor
Clock:
Clock:
Clock:
Clock:
Battery-backed Real Time Clock
with calendar
INDICATORS
...The Nohmad
Nohmad
Nohmad
Nohmad terminal is fitted with two LED sta-
tus indicators.
LH LED flashing Blue
LH LED flashing Blue
LH LED flashing Blue
LH LED flashing Blue: Valid connection to the GSM network.
LH LED steady Blue
LH LED steady Blue
LH LED steady Blue
LH LED steady Blue: Invalid connection to the GSM network.
RH LED off
RH LED off
RH LED off
RH LED off: Normal operation, flashes once when media is read.
RH LED flashes repeatedly
RH LED flashes repeatedly
RH LED flashes repeatedly
RH LED flashes repeatedly: See table below:
REFERENCES
...
...
...
...Other documentation and utilities will relate to
the Nohmad
Nohmad
Nohmad
Nohmad depending on how it is being used:
For use with our Fastlane product MAN060
MAN060
MAN060
MAN060----XX
XX
XX
XX
MAN062
MAN062
MAN062
MAN062----XX
XX
XX
XX
For use with customer software
SDK download
SDK download
SDK download
SDK download
MAN050
MAN050
MAN050
MAN050----XX
XX
XX
XX
MAN051
MAN051
MAN051
MAN051----XX
XX
XX
XX
MAN052
MAN052
MAN052
MAN052----XX
XX
XX
XX
MAN058
MAN058
MAN058
MAN058----XX
XX
XX
XX
Nohmad GPRS Terminal
Nohmad GPRS Terminal
IMPORTANT SAFETY INFORMATION
...
This terminal has been
designed to meet international safety standards but, like any electrical equipment,
care must be taken if safety is to be assured. read these safety instructions before
installation and operation of the terminal. Retain this installation guide for future
use.
DO
DO
DO
DO ensure that all the electrical connections (including
power connections and interconnections between
pieces of equipment) are properly made in accordance
with the manufacturers instructions. Equipment
Equipment
Equipment
Equipment
provided with a safety earth connection must be
provided with a safety earth connection must be
provided with a safety earth connection must be
provided with a safety earth connection must be
earthed
earthed
earthed
earthed
DO
DO
DO
DO consult your dealer if you are in any doubt about
installation, operation or safety of the equipment
DO
DO
DO
DO remember that some equipment continues to
operate after mains power has been removed, because
of an internal battery. In such cases a qualified Service
Engineer must disconnect the battery before
attempting to service the equipment
DO NOT
DO NOT
DO NOT
DO NOT continue to operate the equipment if you are
in any doubt about it working normally
DO NOT
DO NOT
DO NOT
DO NOT remove any cover fastenings unless you are
suitably qualified to do so. Even then isolate from the
power connection before you start
DO NOT
DO NOT
DO NOT
DO NOT allow the equipment to be exposed to rain or
moisture other than permitted by the equipment's
specification
DO NOT
DO NOT
DO NOT
DO NOT attempt to service any battery fitted to the
equipment. If the battery fitted to the circuit board is
faulty, return the complete circuit board to an
approved Service Centre. Removable batteries may be
replaced by suitably qualified Personnel
WARNING
...To comply with international safety standards the a.c. supply must
be routed via an easily accessible isolating device. This device must have a contact
gap of at least 3mm (three millimetres) and should break both Live and Neutral
conductors simultaneously. If the Neutral conductor can be reliably identified the
device may be in the Live conductor only.
POWER REQUIREMENT
...
The Nohmad
Nohmad
Nohmad
Nohmad Attendance Terminal is supplied
with an external low power 5v DC mains adaptor, 0.5W average.
5
6
NO:
CONDITION
ACTION
2
2
2
2
No TCP/IP connection
3
3
3
3
No GPRS connection
LH LED steady
:
Check signal strength
LH LED flashing
:
Check SIM/network pa-
rameters
4
4
4
4
Memory full, no TCP/IP
connection
Check parameters and
host server
5
5
5
5
Memory full, no GPRS con-
nection
LH LED steady:
Check signal strength
LH LED flashing:
Check SIM/network pa-
rameters
6
6
6
6
Memory full, connected, no
server response
Check host software appli-
cation
7
7
7
7
PIN required
Enter a correct PIN
8
8
8
8
SIM fault
Contact supplier
9
9
9
9
SIM fault
Check SIM is fitted
10
10
10
10
Memory full, connected,
faulty server response
Check host software appli-
cation
NOHMAD GPRS TERMINAL
USER GUIDE
MAN061-04
SEPTEMBER 2016
www.touchstar-atc.com
5
www.touchstar-atc.com
6