BUILD-IN TOUCH TERMINAL
TAE 2144
5. Slide the PIM in the direction of the
upward as shown.
6. Remove the PIM from the TP.
12.2 Mounting the PIM onto the Touch Panel
To mount the PIM on a TP, follow the steps below:
1. Ensure that an ESD-compliant working
method is followed (ESD armband, ESD
clothing).
2. Disconnect the device from the supply.
3. Place the TP flat on its back.
4. Place the PIM onto the TP so that the
locking clamps of the PIM are securely
held in the notches of the TP.
5. Slide the PIM in the direction of the arrows
shown.
6. When locking, a “click” can be clearly
heard and the thin upper section of the
PIM is flush with the housing of the TP.
7. Secure the PIM to the TP using the 2
screws provided and a TX-10 Torx
screwdriver with a torque of 0.7 Nm.
09.09.2020