S-DIAS SAFETY DIGITAL INPUT MODULE
SDI 101
02.12.2019
Page 17
3.6
Environmental Conditions
Storage temperature
-20 ... +85 °C
Environmental temperature
0 ... +55 °C
Humidity
0-95 %, non-condensing
Installation altitude above sea
level
0-2000 m without derating
> 2000 m with derating of the maximum environmental temperature by 0.5
°C per 100 m
Operating conditions
Pollution degree 2
EMC resistance
in accordance with 61000-6-7:2015 (Generic standards - Immunity
requirements for equipment intended to perform functions in safety-related
systems (functional safety) at industrial locations)
in accordance with EN 61000-6-2:2007 (industrial area)
(increased requirements in accordance with IEC 62061)
EMC noise generation
in accordance with EN 61000-6-4:2007 (industrial area)
Vibration resistance
EN 60068-2-6
3.5 mm from 5-8.4 Hz
1 g from 8.4-150 Hz
Shock resistance
EN 60068-2-27
15 g
Protection type
EN 60529
IP20