SIGMATEK FDD Step By Step Guide Size 5 to 9
15
Eng
D
Additional Information
Troubleshooting
When the drive detects a fault it will display an error code.
Status Indicators
The table below shows the different status indicators available on the display.
Table 8-1 Status indications
Restoring drive defaults
The drive can be restored to the original factory settings by following the procedure below:
1.
Ensure the drive is not enabled, i.e. terminal 11(or terminal 31 and 35 on FDD3) is open.
2.
Select ‘Def.50 (50 Hz settings) or Def.60 (60 Hz settings)’ in Pr
00
.
3.
Press the red
reset button.
Basic parameters range and default
For information on parameters beyond Pr
00
to Pr
10
refer to the Quick Start Guide.
String
Description
Drive output
stage
The drive is inhibited and cannot be run. The Drive Enable signal is not applied
to the drive enable terminal or is set to 0.
Disabled
The drive is ready to run. The drive enable is active, but the drive inverter is
not active because the final drive run is not active
Disabled
The drive is stopped / holding zero speed.
Enabled
Supply loss condition has been detected
Enabled
The drive is applying dc injection braking
Enabled
The drive has tripped and no longer controlling the motor. The trip code
appears on the display.
Disabled
The drive is in the under voltage state.
Disabled
Parameter
Range (
)
Default (
)
01
Minimum Speed
0.00 to Pr
02
Hz
0.00 Hz
02
Maximum Speed
0.00 to 550.00 Hz
Def.50: 50.00 Hz
Def.60: 60.00 Hz
03
Acceleration Rate 1
0.0 to 32000.0 s
5.0 s
04
Deceleration Rate 1
0.0 to 32000.0 s
10.0 s
05
Drive Configuration
AV (0), AI (1), AV.Pr (2), AI.Pr (3),
PrESEt (4), PAd (5), PAd.rEF (6), E.Pot (7),
torquE (8), Pid (9)
Refer to the
Control
User Guide
for further
information
AV (0)
06
Motor Rated Current
0.00 to Drive Rating Amps
Maximum Heavy Duty
Rating Amps
07
Motor Rated Speed
0.0 to 33000.0 rpm
Def.50: 1500.0 rpm
Def.60: 1800.0 rpm
08
Motor Rated Voltage
0 to 265 V
0 to 530 V
0 to 635 V
110 V drive: 230 V
200 V drive: 230 V
400 V drive Def.50: 400 V
400 V drive Def.60: 460 V
575 V drive: 575 V
09
Motor Rated Power Factor
0.00 to 1.00
0.85
10
User Security Status
Refer to the
Control
User Guide
for further
information
LEVEL.1