AI 022-1
S-DIAS STRAIN GAUGE INPUT MODULE
Page 14
04.11.2020
4.3
Connection Variants
Two connection Types can be used when measuring with strain gauges:
4-wire measurement:
The advantage of this variant is that a 4-pin connector cable can be used for the strain
gauge. The voltage drop over the circuit for the bridge voltage supply however, cannot be
compensated.
6-wire measurement:
This configuration provides the advantage of voltage compensation using the bridge voltage
supply measurement on the strain gauge directly.
Summary of Contents for AI 022-1
Page 8: ...AI 022 1 S DIAS STRAIN GAUGE INPUT MODULE Page 6 04 11 2020...
Page 10: ...AI 022 1 S DIAS STRAIN GAUGE INPUT MODULE Page 8 04 11 2020 2 Mechanical Dimensions...
Page 11: ...S DIAS STRAIN GAUGE INPUT MODULE AI 022 1 04 11 2020 Page 9 3 Connector Layout...
Page 14: ...AI 022 1 S DIAS STRAIN GAUGE INPUT MODULE Page 12 04 11 2020 4 Wiring 4 1 Wiring Example...