background image

6

 

 

1.

 

GENERAL

 

REQUIREMENTS

  

 

1.1

      

Each

 

solar

 

water

 

heater

 

has

 

to

 

be

 

confronted

 

with

 

the

 

general

 

requirements

  

imposed

 

by

 

European

 

standards

 

related

 

to

 

flat

 

solar

 

thermal

 

water

 

heaters

 

quality

 

and

 

performance

 

evaluation.

  

 

Standards

 

are

 

:

 

I

 

)

  ΕΝ 

12975

 

 

1

 

(

 

solar

 

collector

 

general

 

requirements

 

)

  

II

 

)

 ΕΝ 

12975

 

 

2

 

(

 

qualification

 

tests

 

of

 

glazed

 

liquid

 

solar

 

collectors

 

).

 

III)

 ΕΝ 

12976

 

 

1

 

(solar

 

water

 

heating

 

system

 

general

 

requirements)

 

IV)

 ΕΝ 

12976

 

 

2

 

(

 

thermal

 

performance

 

of

 

solar

 

domestic

 

water

 

heating

   

                                        

systems)

 

.

 

 

1.2

     

Solar

 

water

 

heater

 

labeling

  

         

On

 

each

 

solar

 

collector

 

an

 

ineffaceable

 

distinctive

 

label

 

is

 

been

 

stuck

 

(

 

upwards

 

and

 

on

 

the

 

left

 

side

 

)

 

,

 

containing

 

the

 

following

 

data

 

:

 

 

Manufacturer

 

name

  

 

Solar

 

water

 

heater

 

type

  

 

Serial

 

number

  

 

Production

 

year

 Ολική επιφάνεια του συλλέκτη 

/

 των συλλεκτών του 

συστήματος 

 

Collector

 

gross

 

area

 

 

 

Collector

 

aperture

 

area

  

 

Storage

 

tank

 

nominal

 

capacity

  

 

Maximum

 

working

 

pressure

  

 

Working

 

pressure

  

 

Protection

 

against

 

overheating

  

 

All

 

electric

 

parts

 

voltage

  

 

Liquid

  

 

Summary of Contents for SI 150

Page 1: ...1 INSTALLATION AND MAINTENANCE MANUAL SI 150 2...

Page 2: ...CTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT 10 5 SI 150 2 ACCESSORIES 11 6 COLLECTOR COUPLING 12 7 FILLING THE COLLECTOR 13 8 VENTILATION 14 9 STORAGE TANK ELECTRICAL CONNECTION 14 10 LIGHTNING...

Page 3: ...opean Norms related to solar systems qualifications In this pamphlet you will find any details necessary for your solar water heater mantling installation and an excellent state of working conditions...

Page 4: ...4 Warrantee...

Page 5: ...low voltage directive harmonized with the ELOT standards EN 60335 EN 60335 2 21 and DIN 4573 Technical documentation required by the conformity procedure is kept at company headquarters COMPANY A et G...

Page 6: ...12976 1 solar water heating system general requirements IV 12976 2 thermal performance of solar domestic water heating systems 1 2 Solar water heater labeling On each solar collector an ineffaceable d...

Page 7: ...7 2 INSTALLATION INSTRUCTIONS SI 150 2...

Page 8: ...8 SI 150 2 Dimensions and weight 1 Mounting kit dimensions 2 Weights Mounting kit 16 kg Collector empty 40 kg Storage tank empty 60 kg...

Page 9: ...ite directions the two supporting blades that you have already mantle and attach them with the diagonal stabilization blades 3 4 using screws and screw nuts Slightly loose screw Choose the place at yo...

Page 10: ...10 4 SI 150 2 COLLECTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT Having finished mounting kit mantling stabilize the mounting kit on the roof mantling its parts rather loose INSTALLATION STEPS...

Page 11: ...male 1 piece 4 3 Brass male elbow x 1 piece 4 4 Plastic PEX pipe 22 x 3 length 2 50m 1 piece 4 5 Flexible pipe length 0 75m 1 piece 4 6 Female cap 1 piece 4 7 Closed circuit pressure relief safety val...

Page 12: ...12 6 COLLECTOR COUPLING...

Page 13: ...all quantity of water overflows from the short flexible pipe 4 5 sign that collector is full and ventilated 2 Then you connect Filling is done using water and antifreeze The recommended antifreeze is...

Page 14: ...e table i e according to the exterior temperature C under which the system is functioning 8 VENTILATION Special attention is needed to provide adequate ventilation for the collector s so the system ru...

Page 15: ...nect it with collector 11 ANTIFREEZE PROTECTION Depending on the place of the collector s installation there are potential freezing conditions that can cause damage to the collector and the piping Thu...

Page 16: ...ollector to the boiler B with the capacity of the closed system of the storage tank Tables N 1 N 2 TABLE N 1 Propylene glycol solution Temperature Propylene Glycol Water 5 15 85 15 30 70 25 40 60 TABL...

Page 17: ...ny reason there is a need to fill the closed system of the collector with water you should also add antifreeze to retain the ratio according to table No 1 Observe any probable cracking of the collecto...

Page 18: ...ater 2 Valves problem 3 The consumption of hot water is bigger than the appliance s capacity Huge hot water consumption during the night 1 Check the valves and set off the solar water heater valves 2...

Page 19: ...ording papers 1 Date Works Description Accessories Remarks Inspector s name and signature 2 Date Works Description Accessories Remarks Inspector s name and signature 3 Date Works Description Accessori...

Reviews: