MAINTENANCE

 

REQUIREMENTS

 

 

12.1

 

General

 

The

 

collector(s),

 

as

 

all

 

other

 

devices,

 

needs

 

basic

 

maintenance

 

to

 

ensure

 

constant

 

and

 

high

 

performance

 

at

 

all

 

times.

 

There

 

are

 

various

 

actions

 

that

 

can

 

be

 

done

 

by

 

the

 

user;

 

other

 

actions

 

must

 

be

 

carried

 

out

 

by

 

the

 

manufacturer’s

 

licensed

 

service

 

crew.

 

For

 

high

 

performance

 

and

 

long

 

service

 

life

 

of

 

the

 

entire

 

water

 

heating

 ‐ 

distribution

 

installation

 

,

 

maintenance

 

is

 

required

 

and

 

for

 

the

 

rest

 

of

 

installation

 

(boiler,

 

piping,

 

control

 

systems).

 

 

12.2

 

Regular

 

maintenance

 

by

 

the

 

user

 

It

 

is

 

preferred

 

that

 

the

 

user

 

checks

 

twice

 

per

 

year

 

the

 

place

 

where

 

the

 

collector(s)

 

is

 

placed

 

and

 

visually

 

controls

 

the

 

collector

 

and

 

the

 

rest

 

of

 

the

 

components.

 

More

 

specifically:

 

check

   

the

 

leaks

 

in

 

collector’s

 

piping

 

and

 

the

 

leaks

 

in

 

components

 

check

 

for

 

any

 

condensation

 

of

 

the

 

collector

 

check

 

the

 

installation

 

of

 

the

 

collector

 

on

 

the

 

mounting

 

kit

 

and

 

the

 

screws

 

on

 

the

 

mounting

 

kit

 

in

 

order

 

to

 

find

 

any

 

loose

 

screws

 

because

 

of

 

the

 

wind

 

etc.

 

if

 

for

 

any

 

reason

 

there

 

is

 

a

 

need

 

to

 

fill

 

the

 

closed

 

system

 

of

 

the

 

collector

 

with

 

water,

 

you

 

should

 

also

 

add

 

antifreeze

 

to

 

retain

 

the

 

ratio

 

according

 

to

 

table

 

No.

 

1

 

Observe

 

any

 

probable

 

cracking

 

of

 

the

 

collector’s

 

glass

 

‐ 

Observe

 

the

 

clarity

 

of

 

the

 

glass

 

Observe

 

the

 

condition

 

of

 

the

 

piping

 

insulation

 

conveying

 

water

 

from

 

the

 

collector

 

to

 

the

 

boiler

 

 

Cleaning

 

of

 

the

 

collector’s

 

glass,

 

when

 

required,

 

is

 

best

 

done

 

without

 

too

 

much

 

sun.

  

It

 

is

 

recommended

 

that

 

a

 

skilled

 

authorized

 

technician

 

visits

 

the

 

installation

 

in

 

all

 

other

 

cases.

 

In

 

case

 

of

 

glass

 

cracking,

 

the

 

glass

 

should

 

be

 

replaced

 

immediately

 

because

 

there

 

is

 

risk

 

of

 

collector

 

corrosion.

 

 

12.3

 

Maintenance

 

by

 

service

 

crew

 

every

 

three

 

years

 

It

 

is

 

recommended

 

that

 

the

 

following

 

controls

 

shall

 

take

 

place

 

periodically

 

every

 

three

 

years

 

by

 

a

 

licensed

 

team:

 

check

 

glass

 

(cleaning,

 

cracking,

 

shading

 

of

 

collector)

 

check

 

collector’s

 

support

 

on

 

the

 

mounting

 

kit

 

check

 

water

tightness

 

of

 

collectors

 

check

 

insulation

 

of

 

collector

 

It

 

is

 

recommended

 

that

 

the

 

licensed

 

team

 

fill

 

in

 

a

 

printed

 

form

 

quoting

 

the

 

following:

 

works

 

done

 

spare

 

parts

 

possible

 

damages

 

These

 

data

 

appear

 

in

 

the

 

relative

 

maintenance

inspection

 

data

 

sheet

 

in

 

page

 

18.

 

Summary of Contents for SI 150

Page 1: ...1 INSTALLATION AND MAINTENANCE MANUAL SI 150 2...

Page 2: ...CTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT 10 5 SI 150 2 ACCESSORIES 11 6 COLLECTOR COUPLING 12 7 FILLING THE COLLECTOR 13 8 VENTILATION 14 9 STORAGE TANK ELECTRICAL CONNECTION 14 10 LIGHTNING...

Page 3: ...opean Norms related to solar systems qualifications In this pamphlet you will find any details necessary for your solar water heater mantling installation and an excellent state of working conditions...

Page 4: ...4 Warrantee...

Page 5: ...low voltage directive harmonized with the ELOT standards EN 60335 EN 60335 2 21 and DIN 4573 Technical documentation required by the conformity procedure is kept at company headquarters COMPANY A et G...

Page 6: ...12976 1 solar water heating system general requirements IV 12976 2 thermal performance of solar domestic water heating systems 1 2 Solar water heater labeling On each solar collector an ineffaceable d...

Page 7: ...7 2 INSTALLATION INSTRUCTIONS SI 150 2...

Page 8: ...8 SI 150 2 Dimensions and weight 1 Mounting kit dimensions 2 Weights Mounting kit 16 kg Collector empty 40 kg Storage tank empty 60 kg...

Page 9: ...ite directions the two supporting blades that you have already mantle and attach them with the diagonal stabilization blades 3 4 using screws and screw nuts Slightly loose screw Choose the place at yo...

Page 10: ...10 4 SI 150 2 COLLECTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT Having finished mounting kit mantling stabilize the mounting kit on the roof mantling its parts rather loose INSTALLATION STEPS...

Page 11: ...male 1 piece 4 3 Brass male elbow x 1 piece 4 4 Plastic PEX pipe 22 x 3 length 2 50m 1 piece 4 5 Flexible pipe length 0 75m 1 piece 4 6 Female cap 1 piece 4 7 Closed circuit pressure relief safety val...

Page 12: ...12 6 COLLECTOR COUPLING...

Page 13: ...all quantity of water overflows from the short flexible pipe 4 5 sign that collector is full and ventilated 2 Then you connect Filling is done using water and antifreeze The recommended antifreeze is...

Page 14: ...e table i e according to the exterior temperature C under which the system is functioning 8 VENTILATION Special attention is needed to provide adequate ventilation for the collector s so the system ru...

Page 15: ...nect it with collector 11 ANTIFREEZE PROTECTION Depending on the place of the collector s installation there are potential freezing conditions that can cause damage to the collector and the piping Thu...

Page 16: ...ollector to the boiler B with the capacity of the closed system of the storage tank Tables N 1 N 2 TABLE N 1 Propylene glycol solution Temperature Propylene Glycol Water 5 15 85 15 30 70 25 40 60 TABL...

Page 17: ...ny reason there is a need to fill the closed system of the collector with water you should also add antifreeze to retain the ratio according to table No 1 Observe any probable cracking of the collecto...

Page 18: ...ater 2 Valves problem 3 The consumption of hot water is bigger than the appliance s capacity Huge hot water consumption during the night 1 Check the valves and set off the solar water heater valves 2...

Page 19: ...ording papers 1 Date Works Description Accessories Remarks Inspector s name and signature 2 Date Works Description Accessories Remarks Inspector s name and signature 3 Date Works Description Accessori...

Reviews: