background image

1

 

 

 
 

 
 
 
 

INSTALLATION

 

AND

 

MAINTENANCE

 

MANUAL

 

SI

 

150

 

/

 

2

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 

Summary of Contents for SI 150

Page 1: ...1 INSTALLATION AND MAINTENANCE MANUAL SI 150 2...

Page 2: ...CTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT 10 5 SI 150 2 ACCESSORIES 11 6 COLLECTOR COUPLING 12 7 FILLING THE COLLECTOR 13 8 VENTILATION 14 9 STORAGE TANK ELECTRICAL CONNECTION 14 10 LIGHTNING...

Page 3: ...opean Norms related to solar systems qualifications In this pamphlet you will find any details necessary for your solar water heater mantling installation and an excellent state of working conditions...

Page 4: ...4 Warrantee...

Page 5: ...low voltage directive harmonized with the ELOT standards EN 60335 EN 60335 2 21 and DIN 4573 Technical documentation required by the conformity procedure is kept at company headquarters COMPANY A et G...

Page 6: ...12976 1 solar water heating system general requirements IV 12976 2 thermal performance of solar domestic water heating systems 1 2 Solar water heater labeling On each solar collector an ineffaceable d...

Page 7: ...7 2 INSTALLATION INSTRUCTIONS SI 150 2...

Page 8: ...8 SI 150 2 Dimensions and weight 1 Mounting kit dimensions 2 Weights Mounting kit 16 kg Collector empty 40 kg Storage tank empty 60 kg...

Page 9: ...ite directions the two supporting blades that you have already mantle and attach them with the diagonal stabilization blades 3 4 using screws and screw nuts Slightly loose screw Choose the place at yo...

Page 10: ...10 4 SI 150 2 COLLECTOR AND STORAGE TANK INSTALLATION ON MOUNTING KIT Having finished mounting kit mantling stabilize the mounting kit on the roof mantling its parts rather loose INSTALLATION STEPS...

Page 11: ...male 1 piece 4 3 Brass male elbow x 1 piece 4 4 Plastic PEX pipe 22 x 3 length 2 50m 1 piece 4 5 Flexible pipe length 0 75m 1 piece 4 6 Female cap 1 piece 4 7 Closed circuit pressure relief safety val...

Page 12: ...12 6 COLLECTOR COUPLING...

Page 13: ...all quantity of water overflows from the short flexible pipe 4 5 sign that collector is full and ventilated 2 Then you connect Filling is done using water and antifreeze The recommended antifreeze is...

Page 14: ...e table i e according to the exterior temperature C under which the system is functioning 8 VENTILATION Special attention is needed to provide adequate ventilation for the collector s so the system ru...

Page 15: ...nect it with collector 11 ANTIFREEZE PROTECTION Depending on the place of the collector s installation there are potential freezing conditions that can cause damage to the collector and the piping Thu...

Page 16: ...ollector to the boiler B with the capacity of the closed system of the storage tank Tables N 1 N 2 TABLE N 1 Propylene glycol solution Temperature Propylene Glycol Water 5 15 85 15 30 70 25 40 60 TABL...

Page 17: ...ny reason there is a need to fill the closed system of the collector with water you should also add antifreeze to retain the ratio according to table No 1 Observe any probable cracking of the collecto...

Page 18: ...ater 2 Valves problem 3 The consumption of hot water is bigger than the appliance s capacity Huge hot water consumption during the night 1 Check the valves and set off the solar water heater valves 2...

Page 19: ...ording papers 1 Date Works Description Accessories Remarks Inspector s name and signature 2 Date Works Description Accessories Remarks Inspector s name and signature 3 Date Works Description Accessori...