background image

14811

 • 

January 2005

 • 

Operation

Page

 

9

Configurable Parameters/Menu Items

Note: What follows is a discussion of the configurable parameters in the DA5320. To
view a diagram of the flow of the menu structure with simple operating instructions,
see the section of the manual entitled MENU STRUCTURE that follows this
discussion.

There are a number of items that are configurable on the DA5320. These fall into two basic 
categories - Input Parameters and Output Parameters. Additionally, there are some diag-
nostic, reset and memory storage functions that can be accessed from the front panel 
through the menu commands.

Input Parameters

Each DA5320 is an 8X8 AES Digital Audio router that can route the signals that are physi-
cally connected to it 

or any of the other 56 channels available on the OctaBus™

. Which of 

the available signals it should consider to be Inputs is defined under the  menu item. 
With this menu item the operator defines, by selecting the OctaBus™ ID and the channel 
number, exactly which signal on the OctaBus™ should be defined as each of the num-
bered inputs (1-8) to the module being configured, without regard to the physically con-
nected inputs to the module.

NOTE: If OctaBus™ is not enabled, requests for inputs defined as being from other 
modules (OctaBus™ ID’s other than 1), will generate an ERROR condition. 

Each of the defined inputs may also have a gain value assigned to them to adjust their 

incoming level to the mixer or router stages. This gain adjust is adjusted via the  

menu item that appears under the  main menu selection by specifying the gain factor 
for each channel. The gain can be adjusted in 1 dB increments. 

Output Parameters

Due to the nature of some of the parameters able to be modified, for example enabling out-
puts, it may be desired to change all or selected groups of outputs simultaneously. To 
accommodate this, grouping of outputs is provided. Output grouping does not apply to rout-
ing functions in the DA5320 . Output grouping is the first parameter detailed in this section.

If the module being configured is to be a part of a system that utilizes the OctaBus™, this 
feature must be activated. This feature is detailed in the OctaBus™ ID Assignment section 
below.

To operate as a 64 X 8 channel router, the definiton of which of the defined inputs should 
be routed to specific outputs must be detailed. As a mixer, which inputs will be mixed as 
they are directed to the outputs must also be defined. Finally, the level of the signal to be 

Summary of Contents for DA5320

Page 1: ...Document No 14811 January 2005 DA5320 8 CHANNEL AES AUDIO MIXER ROUTER MODULE...

Page 2: ...14811 January 2005 Front Matter Page ii...

Page 3: ...licable European Union CE regulations and recommendations COPYRIGHT AND TRADEMARKS Copyright 2004 SIGMA ELECTRONICS Inc All rights reserved Printed in USA SIGMA ELECTRONICS is a registered trademark o...

Page 4: ...s arise which you cannot resolve or if there are any questions regarding this equipment or information about other products manufactured by SIGMA ELECTRONICS please contact your local representative o...

Page 5: ...is needed PRODUCT SCOPE This module has the capability to perform two distinct functions 1 As a member of the Sigma OctaStream product family it includes the OctaBus TDM interconnect This allows the D...

Page 6: ...form the following checks immediately Inspect the shipping container s for damage If you find any damage to the containers carefully inspect the product for damage If any damage is discovered notify...

Page 7: ...existing frame does not have the required backplane replacement backplanes are available from Sigma Electronics and can easily be installed in the field Power The S5000 Signal Management System frame...

Page 8: ...lding knurled knob push until module is completely seated in cardedge connector on backplane 5 Reinstall front door required for proper operation of S5000 Signal Management System frame see Caution ab...

Page 9: ...F G H I J OCTABUS OUTPUT OCTABUS INPUT AES INPUT 1 AES INPUT 2 AES INPUT 3 AES INPUT 4 AES OUTPUT 1 AES OUTPUT 2 AES OUTPUT 3 AES OUTPUT 4 A B C D E F G H I J OCTABUS OUTPUT OCTABUS INPUT AES INPUT 1...

Page 10: ...an invalid operating condition exists within the DA5320 These errors fall into three categories power on self test failure missing inputs or problems with the OctaBus a Power On Errors cycle the power...

Page 11: ...en the display is blinking Pressing the TAKE button immediately after a valid store will return the DA5320 to the idle display see below 7 SEGMENT DISPLAY The 7 segment display is used to display conf...

Page 12: ...nnel delay Parameter Configuration Activate the menu display and navigate through the menu to the edit screen for the param eter to be configured Pressing the UP or DOWN arrows will change the display...

Page 13: ...cally con nected inputs to the module NOTE If OctaBus is not enabled requests for inputs defined as being from other modules OctaBus ID s other than 1 will generate an ERROR condition Each of the defi...

Page 14: ...dependent Each channel s parameters are set individually b Pair Output pairs as defined by the output settings have their parameters set together When the PAIR mode is active only the odd channels wil...

Page 15: ...d via the serial port on the rear of the S5000 frame If a mix has been defined in this manner that is not able to be displayed through the front panel selection the display will show indicating that t...

Page 16: ...of the signal connected to each output All values will be set correlating the actual inputs of the module to its equivalent output In 1 to Out 1 In 2 to Out 2 In 3 to Out 3 etc c ALL This type of res...

Page 17: ...onfiguration Parameter Storage All configuration data can be stored in the FlashROM to preserve it in the event of a loss of power On power up all settings will be returned to their previous settings...

Page 18: ...raphic display of the menu structure is provided to give the user an overall view of the commands that are accessible via the front panel controls Detailed explana tions of each parameter have been pr...

Page 19: ...14811 January 2005 Menu Structure Page 15 Note around character indicates character will be blinking data entry mode active...

Page 20: ...SH DIAGNOSTICS Status Only RESET Reset Board Reset All Reset Outputs Reset Inputs Current ON OFF setting shown Change using ARROW button then press Current ON OFF setting shown Change using ARROW butt...

Page 21: ...14811 January 2005 Menu Structure Page 17 NOTES...

Reviews: