background image

14811

 • 

January 2005

 • 

System Components

Page

 

3

SYSTEM COMPONENTS

Frame

The DA5320 module is engineered to operate in a Sigma S5000 Signal Management 
Frame. This frame provides all the necessary interface components and power for opera-
tion of the DA5320 module.

Interface Components

To accommodate a variety of connector requirements necessary for the signal formats 
accepted by the S5000 Signal Management System, a number of backplanes are avail-
able. The DA5320 requires either an RP302 Twisted Pair I/O or RP303 BNC I/O Back-
plane. 

Each S5000 Signal Management System frame is supplied with two (2) backplanes. The 
required backplane(s) is specified at the time of order. If an existing frame does not have 
the required backplane, replacement backplanes are available from Sigma Electronics and 
can easily be installed in the field.

Power

The S5000 Signal Management System frame provides the required power to operate the 
DA5320 via the backplane adapter. Dual power supplies are available for redundant appli-
cations.

Modules

The DA5320 consists of a single-slot card containing a front panel interface of switches, 
indicator LED’s and a four-digit, seven-segment LED display. Via this interface all common 
configuration settings and status indications are available to the user.

Optionally, if a CI5705 Communications Interface Adapter is installed in the S5000 Signal 
Management System frame, the DA5320 may be configured and controlled from a remote 
location via the EIA-485 port. The CI5705 is also necessary if an external video reference 
is required.

Summary of Contents for DA5320

Page 1: ...Document No 14811 January 2005 DA5320 8 CHANNEL AES AUDIO MIXER ROUTER MODULE...

Page 2: ...14811 January 2005 Front Matter Page ii...

Page 3: ...licable European Union CE regulations and recommendations COPYRIGHT AND TRADEMARKS Copyright 2004 SIGMA ELECTRONICS Inc All rights reserved Printed in USA SIGMA ELECTRONICS is a registered trademark o...

Page 4: ...s arise which you cannot resolve or if there are any questions regarding this equipment or information about other products manufactured by SIGMA ELECTRONICS please contact your local representative o...

Page 5: ...is needed PRODUCT SCOPE This module has the capability to perform two distinct functions 1 As a member of the Sigma OctaStream product family it includes the OctaBus TDM interconnect This allows the D...

Page 6: ...form the following checks immediately Inspect the shipping container s for damage If you find any damage to the containers carefully inspect the product for damage If any damage is discovered notify...

Page 7: ...existing frame does not have the required backplane replacement backplanes are available from Sigma Electronics and can easily be installed in the field Power The S5000 Signal Management System frame...

Page 8: ...lding knurled knob push until module is completely seated in cardedge connector on backplane 5 Reinstall front door required for proper operation of S5000 Signal Management System frame see Caution ab...

Page 9: ...F G H I J OCTABUS OUTPUT OCTABUS INPUT AES INPUT 1 AES INPUT 2 AES INPUT 3 AES INPUT 4 AES OUTPUT 1 AES OUTPUT 2 AES OUTPUT 3 AES OUTPUT 4 A B C D E F G H I J OCTABUS OUTPUT OCTABUS INPUT AES INPUT 1...

Page 10: ...an invalid operating condition exists within the DA5320 These errors fall into three categories power on self test failure missing inputs or problems with the OctaBus a Power On Errors cycle the power...

Page 11: ...en the display is blinking Pressing the TAKE button immediately after a valid store will return the DA5320 to the idle display see below 7 SEGMENT DISPLAY The 7 segment display is used to display conf...

Page 12: ...nnel delay Parameter Configuration Activate the menu display and navigate through the menu to the edit screen for the param eter to be configured Pressing the UP or DOWN arrows will change the display...

Page 13: ...cally con nected inputs to the module NOTE If OctaBus is not enabled requests for inputs defined as being from other modules OctaBus ID s other than 1 will generate an ERROR condition Each of the defi...

Page 14: ...dependent Each channel s parameters are set individually b Pair Output pairs as defined by the output settings have their parameters set together When the PAIR mode is active only the odd channels wil...

Page 15: ...d via the serial port on the rear of the S5000 frame If a mix has been defined in this manner that is not able to be displayed through the front panel selection the display will show indicating that t...

Page 16: ...of the signal connected to each output All values will be set correlating the actual inputs of the module to its equivalent output In 1 to Out 1 In 2 to Out 2 In 3 to Out 3 etc c ALL This type of res...

Page 17: ...onfiguration Parameter Storage All configuration data can be stored in the FlashROM to preserve it in the event of a loss of power On power up all settings will be returned to their previous settings...

Page 18: ...raphic display of the menu structure is provided to give the user an overall view of the commands that are accessible via the front panel controls Detailed explana tions of each parameter have been pr...

Page 19: ...14811 January 2005 Menu Structure Page 15 Note around character indicates character will be blinking data entry mode active...

Page 20: ...SH DIAGNOSTICS Status Only RESET Reset Board Reset All Reset Outputs Reset Inputs Current ON OFF setting shown Change using ARROW button then press Current ON OFF setting shown Change using ARROW butt...

Page 21: ...14811 January 2005 Menu Structure Page 17 NOTES...