  Scope User Interface 

 

  Company Logo. 

  Channel label/waveform, different channels are marked with different colors, the color of the 

waveform is consistent with the color of the channel. 

  Working state, including Arm, Ready, Trig

’d, Stop, FStop, Auto and Roll. 

  Horizontal time base, indicating the duration of each grid is 200us. 

  Delay, the time of the screen center position relative to the waveform trigger position. 

  The waveform trigger position, press 

  to move to the left or right. 

  The frequency meter, indicating the frequency of the trigger source. 

  Power icon. When the icon is green, it indicates that the battery is charging, and when it is red, 

it indicates that the battery is low. 

  Real-time display. 

  Trigger level position, press 

  , and adjust the universal knob to modify the trigger level. 

  Indicates the USB flash drive is connected. 

  Indicates the current sample rate and memory depth of the oscilloscope. 

 

:Indicates the trigger source selected, different labels are displayed when different trigger 

source are selected and the color of the trigger parameter area will change accordingly. 

Indicates the current trigger coupling mode is DC coupling, 

  Indicates the current trigger 

type is rising edge trigger. 

 

:Indicates CH1 open,

Indicates the channel is in DC coupling mode,

Indicates 

the voltage of each grid is 2V. 

  Softkey function menu. 

 

Summary of Contents for SHS1000X Series

Page 1: ...SHS800X SHS1000X Handheld Digital Oscilloscope QS_EN01D Quick Start...

Page 2: ......

Page 3: ...or change parts of or all the specifications or pricing policies at the company s sole decision Information in this publication replaces all previously corresponding material Any method of copying ext...

Page 4: ...YRIGHT INFORMATION I GENERAL SAFETY SUMMARY 1 SAFETY TERMS AND SYMBOLS 1 MEASUREMENT CATEGORY 2 QUICK START 3 INTRODUCTION OF SCOPE PANEL 7 INTRODUCTION OF METER PANEL 12 INTRODUCTION OF RECORDER PANE...

Page 5: ...meaning of symbols symbol meaning symbol meaning Warning Power Switch Hazardous Voltage Equipment meeting double insulation or reinforced insulation EarthGround Indoor use only Lithium battery failure...

Page 6: ...to the mains such as a circuit board powered by a battery or a secondary circuit with special protection This measurement category is also called CAT CAT II For measurements installed in buildings su...

Page 7: ...SHS800X SHS1000X Quick Start 3 Quick Start Product Appearance SHS800X SHS1000X...

Page 8: ...shown in Figure 1 2 Remove the battery cover as shown in Figure2 3 Put the battery into the battery slot as shown in Figure3 4 Lock the screws with the screwdriver as shown in Figure 1 and then turn o...

Page 9: ...compensated before their first use with the oscilloscope The following steps illustrate the proper probe compensation procedure 1 Connect probe to the CH1 Input Terminal and the Compensation Signal O...

Page 10: ...ut terminals according to the marking prompt of the front panel When measuring the current please select the correct accessories according to the current 3 Current Adapter To test current insert a cur...

Page 11: ...oduction of Scope Panel LCD Display Trigger Control Menu Softkey Single function Control Buttons Multifunction Control Buttons Power Button Universal Knob Multimeter Inputs Vertical Control Oscillosco...

Page 12: ...s to set delay to zero quickly Trigger Control Push to open trigger menu This oscilloscope provides various trigger types Detailed usage of trigger control is described in the user manual Push to ligh...

Page 13: ...al and track cursor mode Print Quick print picture It is preferentially stored in USB flash disk or local path Menu On Off Controls the hiding and display of the screen menu Clear Sweeps Press this bu...

Page 14: ...acquire menu You can set the acquisition mode Normal Peak Detect Average Eres interpolation mode Sinx X or linear and memory depth You could enable the XY function and sequence function Display Persis...

Page 15: ...icon When the icon is green it indicates that the battery is charging and when it is red it indicates that the battery is low Real time display Trigger level position press and adjust the universal kn...

Page 16: ...12 SHS800X SHS1000X Quick Start Introduction of Meter Panel Meter Button Universal Knob Menu Softkey Hold Button...

Page 17: ...top the meter measurement The status HOLD will be displayed on the upper left of the screen Meter User Interface Coupling type of the meter is DC Measurement range is set in manual mode Measurement va...

Page 18: ...al Knob Menu Softkey Introduction of Function Menus Button Description Recorder Button Press to enter Recorder mode F1 F5 Press to active sample logger or measurement logger Universal Knob Use the kno...

Page 19: ...remaining storage space at the current sampling rate If it is in the playback mode it indicates the total time of the data Indicate the status of the data source Indicates the time that recorder start...

Page 20: ...ndicates the time that recorder starts working Indicates how long it took to record data Indicates memory usage The first line represents the total available time of the remaining storage space the se...

Page 21: ...Interface Glance The Right Side Panel USB Device Connects with a PC for remote control USB Host Port Probe Compensation Ground Terminal Hand strap installation slot The Left Side Panel Hand strap inst...

Page 22: ...ent after completing inspections above 5 If it still does not work normally please contact SIGLENT 2 After the signal is sampled there is no corresponding waveform displaying 1 Check if the probe is c...

Page 23: ...middle or change the trigger Mode to Auto Note press Auto Setup could automatically replace the above setting 6 The waveform displays like ladder 1 The horizontal time scale may be too low you can in...

Page 24: ...oscilloscope was launched in 2005 SIGLENT has become the fastest growing manufacturer of digital oscilloscopes We firmly believe that today SIGLENT is the best value in electronic test measurement Hea...

Reviews: