SIGLENT SHS1000X Series Quick Start Manual Download Page 12

 

8                                                                                                                                            SHS800X/SHS1000X  Quick  Start 

  Vertical Control 

 

 

Analog channel on/off or channel is selected to change. 

 

Push to increase the vertical scale of selected channel 

 

Push to decrease. 

 

Push to increase the vertical offset of selected channel 

 

Push to decrease. 

When 

  is lit, press 

  to set offset to zero quickly. 

 

  Horizontal Control 

 

 

Push to increase the timebase 

 

Push to decrease 

 

Push to move the waveform to left 

 

Push to move to right. 

When 

  is lit, press 

  to set delay to zero quickly. 

 

  Trigger Control 

 

 

Push  to  open  trigger  menu.  This  oscilloscope 
provides  various  trigger  types.  Detailed  usage  of 
trigger control is described in the user manual. 

 

Push  to  light  up  the  button  light,  adjusting  the 
universal knob can change the trigger level 

 

 

Universal Knob 

 

During menu operation, when the light in the upper left corner of the knob is 
on, you can turn the knob to select among the submenus under the current 
menu, and press down to select the current submenu. Additionally, it can also 
be used to modify parameters and input filenames. 

 

For more detailed usage information, please refer to the user manual. 

 

Summary of Contents for SHS1000X Series

Page 1: ...SHS800X SHS1000X Handheld Digital Oscilloscope QS_EN01D Quick Start...

Page 2: ......

Page 3: ...or change parts of or all the specifications or pricing policies at the company s sole decision Information in this publication replaces all previously corresponding material Any method of copying ext...

Page 4: ...YRIGHT INFORMATION I GENERAL SAFETY SUMMARY 1 SAFETY TERMS AND SYMBOLS 1 MEASUREMENT CATEGORY 2 QUICK START 3 INTRODUCTION OF SCOPE PANEL 7 INTRODUCTION OF METER PANEL 12 INTRODUCTION OF RECORDER PANE...

Page 5: ...meaning of symbols symbol meaning symbol meaning Warning Power Switch Hazardous Voltage Equipment meeting double insulation or reinforced insulation EarthGround Indoor use only Lithium battery failure...

Page 6: ...to the mains such as a circuit board powered by a battery or a secondary circuit with special protection This measurement category is also called CAT CAT II For measurements installed in buildings su...

Page 7: ...SHS800X SHS1000X Quick Start 3 Quick Start Product Appearance SHS800X SHS1000X...

Page 8: ...shown in Figure 1 2 Remove the battery cover as shown in Figure2 3 Put the battery into the battery slot as shown in Figure3 4 Lock the screws with the screwdriver as shown in Figure 1 and then turn o...

Page 9: ...compensated before their first use with the oscilloscope The following steps illustrate the proper probe compensation procedure 1 Connect probe to the CH1 Input Terminal and the Compensation Signal O...

Page 10: ...ut terminals according to the marking prompt of the front panel When measuring the current please select the correct accessories according to the current 3 Current Adapter To test current insert a cur...

Page 11: ...oduction of Scope Panel LCD Display Trigger Control Menu Softkey Single function Control Buttons Multifunction Control Buttons Power Button Universal Knob Multimeter Inputs Vertical Control Oscillosco...

Page 12: ...s to set delay to zero quickly Trigger Control Push to open trigger menu This oscilloscope provides various trigger types Detailed usage of trigger control is described in the user manual Push to ligh...

Page 13: ...al and track cursor mode Print Quick print picture It is preferentially stored in USB flash disk or local path Menu On Off Controls the hiding and display of the screen menu Clear Sweeps Press this bu...

Page 14: ...acquire menu You can set the acquisition mode Normal Peak Detect Average Eres interpolation mode Sinx X or linear and memory depth You could enable the XY function and sequence function Display Persis...

Page 15: ...icon When the icon is green it indicates that the battery is charging and when it is red it indicates that the battery is low Real time display Trigger level position press and adjust the universal kn...

Page 16: ...12 SHS800X SHS1000X Quick Start Introduction of Meter Panel Meter Button Universal Knob Menu Softkey Hold Button...

Page 17: ...top the meter measurement The status HOLD will be displayed on the upper left of the screen Meter User Interface Coupling type of the meter is DC Measurement range is set in manual mode Measurement va...

Page 18: ...al Knob Menu Softkey Introduction of Function Menus Button Description Recorder Button Press to enter Recorder mode F1 F5 Press to active sample logger or measurement logger Universal Knob Use the kno...

Page 19: ...remaining storage space at the current sampling rate If it is in the playback mode it indicates the total time of the data Indicate the status of the data source Indicates the time that recorder start...

Page 20: ...ndicates the time that recorder starts working Indicates how long it took to record data Indicates memory usage The first line represents the total available time of the remaining storage space the se...

Page 21: ...Interface Glance The Right Side Panel USB Device Connects with a PC for remote control USB Host Port Probe Compensation Ground Terminal Hand strap installation slot The Left Side Panel Hand strap inst...

Page 22: ...ent after completing inspections above 5 If it still does not work normally please contact SIGLENT 2 After the signal is sampled there is no corresponding waveform displaying 1 Check if the probe is c...

Page 23: ...middle or change the trigger Mode to Auto Note press Auto Setup could automatically replace the above setting 6 The waveform displays like ladder 1 The horizontal time scale may be too low you can in...

Page 24: ...oscilloscope was launched in 2005 SIGLENT has become the fastest growing manufacturer of digital oscilloscopes We firmly believe that today SIGLENT is the best value in electronic test measurement Hea...

Reviews: