40
Copyright © Sigicom AB 2003-2013
INFRA MASTER
NOTE
The green LED on the front panel is lit (not flashing)
while transients are being transferred from the nodes to
the INFRA Master. Do not stop measurement or discon-
nect any connection during this, unless you can accept
loss of last triggered transient files.
1.
In the
Master Unit
category,
see Menu Tree in section 6.2,
enter
Working Mode Setup
,
which is the first menu in this
category.
2.
The password is a sequence of
[UP] and [DOWN] presses:
▲ ▼ ▲ ▼ ▼ ▲ ▼ ▲
3.
Press [F2] to
Edit
.
4.
Press [DOWN] to change
OFF
to
ON
, or vice versa.
5.
Press [F2] to
Save
the new
setting.
Comm
Lo. batt
Reg. On
LCD
F1
F2
Working mode setup:
OFF
1Back
2Edit
3
6.3.2.2 Toggle between REG ON/OFF when Quick Reg. Mode is OFF
Comm
Lo. batt
Reg. On
LCD
F1
F2
Working mode setup:
OFF
1Back
2Edit
4