6
6
3
2
hardware
version
string
Read
8
8
3
2
device ID
hex
Read
Product ID
10
A
3
4
device PAC
hex
Read
Product PAC
14
E
3
1
SENSOR_TYPE
1-255
uint16
Read
Sensor or
Input Type
Modbus
Register
(Decimal)
Modbus
Register
(Hex)
Function
Code
(Read)
Function
Code
(Write)
# of
Registers
Description
Range
Default
Format
Property
Comment
270
10E
3
16
4
CURRENT_CONFIGURATION
hex
Read/Write
274
112
3
16
1
SERVER_CONFIG
uint16
Read /
Write
0: Send to
Sigfox
Network
1: Send to
Dongle
276
114
3
16
1
RADIO_CONFIG
1, 2, 4
4
uint16
Read /
Write
RC zones
selection
1, 2 ,4 is
RCZ1,
RCZ2,
RCZ4
277
115
3
16
1
TX_POWER
20
int16
Read /
Write
RF Tx
power
278
116
3
16
2
CONSTANT_A
1
float
Read /
Write
Constant a
for scaling
measured
value
280
118
3
16
2
CONSTANT_B
0
float
Read /
Write
Constant b
for scaling
measured
value
282
11A
3
16
2
HIGH_CUT
1E+09
float
Read /
Write
High cut
value for
calculated
value
284
11C
3
16
2
LOW_CUT
-1E+09
float
Read /
Write
Low cut
value for
calculated
value
286
11E
3
16
2
SENSOR_BOOT_TIME
200
uint32
Read /
Write
Boot time
of
sensor/input,
in ms
306
132
3
16
2
SYSTEM_SENSITIVITY
11
float
Read /
Write
The
sensitivity
of the
circuit
(mV/ppm)
Using the configuration cable to connect to the sensor as below picture.
6.2 Configuration table