25
•
Place the new copper/brass washer in, then screw in the new seat into
the bottom casting until tight but not so tight as to damage the
aluminum
threads of the casting (35 inch pounds).
•
Place the new needle in the groove of the float and insert the float pin
through the bracket and float, then snug up the float screw.
•
Loosen the float screw so the bracket will move up and down and
adjust the bracket so when pushing on the needle the top of the float
will be parallel with the top of the casting. It is very important to keep
the float from binding on the stem guide as it moves up and down.
•
Replace the top casting into the bottom casting so the metering stem
slides in to the metering guide.
•
Replace the 4 top screws snugly, and move the control knob up and
down while tightening the 4 screws. Once tight the control knob
should move up and down freely in any position.
•
Meter the valve to the specifications above and check the overflow
fuel line ( if the float is operating correctly and adjusted parallel to the
casting the oil level in the valve will be correct.
The metering screw/high fire screw can also be replaced from the valve
rebuild kit, or kept as a spare.
Summary of Contents for Sig100
Page 10: ...10 Heater Installation Diagram ...
Page 20: ...20 ...
Page 26: ...26 Oil Metering Valve Diagram ...