15
2.4 TIG Spot Display
INSTALLATION & OPERATION
1
§3.2.5 TIG Spot display introduction
1. Current display
: 10-400A (320A for BT TIG 321).
2. T
on
display
: 0.1 - 1.0s.
3. T
off
display
: off - 10.0s.
§3.2.6 JOB Program introduction
1. Welding mode display
: Here are selected welding states.
2. Parameters display
: Here are all selected parameters values.
3. JOB number
: A total 1-10 JOB numbers can store or call the selected parameters
by JOB key.
4. Load/ Delete display
: Press Function A/B key to call/delete parameters setting for
the selected JOB number.
1. Current display:
10-400A (320A for BT TIG 321).
2. Ton display:
0.1 - 1.0s.
3. Toff display:
off - 10.0s.
2.5 JOB Programme
INSTALLATION & OPERATION
1
§3.2.5 TIG Spot display introduction
1. Current display
: 10-400A (320A for BT TIG 321).
2. T
on
display
: 0.1 - 1.0s.
3. T
off
display
: off - 10.0s.
§3.2.6 JOB Program introduction
1. Welding mode display
: Here are selected welding states.
2. Parameters display
: Here are all selected parameters values.
3. JOB number
: A total 1-10 JOB numbers can store or call the selected parameters
by JOB key.
4. Load/ Delete display
: Press Function A/B key to call/delete parameters setting for
the selected JOB number.
1. Welding mode display:
Here are selected welding states.
2. Parameters display:
Here are all selected parameters values.
3. JOB number:
A total 1-10 JOB numbers can store or call the selected parameters by JOB key.
4. Load/ Delete display:
Press Function A/B key to call/delete parameters setting for the selected
JOB number.