![SifWeld Evolution TS200DC Operation Manual Download Page 13](http://html.mh-extra.com/html/sifweld/evolution-ts200dc/evolution-ts200dc_operation-manual_1267112013.webp)
13
INSTALLATION & OPERATION
1
§3.2.3 HF/LIFT TIG display introduction
1. SETING button
: Press it to lock “SETING” interface, then turn the Parameters
select/adjust knob to select TIG LIFT or TIG HF welding mode.
2. Parameters select/adjust knob
: turn it to select welding mode or value, such as
current, Down Slope and Post-Flow. Press it to select parameters or function mode.
3. Trigger mode button
: You can select 2T or 4T trigger mode.
*
4. Function
: When locking “SETING” interface, you can press the parameters
select/adjust knob to select function, such as PULSE, NO PULSE and SPOT. SPOT
is only available in TIG HF welding mode.
5. Value display
: Here is value of the currently selected parameter, such as current,
Down Slope and Post-Flow.
6. TIG parameter display
.
*
*
Denotes more detailed explanation of function to follow.
Further Controls Explained
Trigger mode button (3)
2T Mode
The trigger is pulled and held on to activate the welding circuit, when the trigger is
2.2 HF/LIFT TIG Display
1. SETTING button
Press it to lock “SETTING” interface, then turn the Parameters select/adjust knob to select TIG LIFT or TIG
HF welding mode.
2. Parameters select/adjust knob
Turn it to select welding mode or value, such as current, Down Slope and Post-Flow. Press it to select
parameters or function mode.
3. Trigger mode button
You can select 2T or 4T trigger mode.
4. Function
When locking “SETTNG” interface, you can press the parameters select/adjust knob to select function,
such as PULSE, NO PULSE and SPOT. SPOT is only available in TIG HF welding mode.
5. Value display
Here is value of the currently selected parameter, such as current, Down Slope and Post-Flow.
6. TIG parameter display
Further Controls Explained
Trigger mode button (3)
2T Mode
The trigger is pulled and held on to activate the welding circuit, when the trigger is released, the
welding circuit stops.
Summary of Contents for Evolution TS200DC
Page 27: ...27 Notes ...