![SifWeld Evolution TS200DC Operation Manual Download Page 11](http://html.mh-extra.com/html/sifweld/evolution-ts200dc/evolution-ts200dc_operation-manual_1267112011.webp)
11
2. Control Panels
INSTALLATION & OPERATION
1
§3.2 Layout for Control panel
§3.2.1 Control panel
1. Screen
: It will show all welding parameters, such as welding voltage, welding current
and other parameters set.
2. SETING button.*
3. Parameters select/adjust knob.*
4. Trigger mode selection
: Press it to select 2T or 4T trigger mode.
*
Denotes more detailed explanation of function to follow.
Further Controls Explained
SETING button (2)
Press it to lock “SETING” interface and press again or wait for 2s to unlock. In
“SETING” interface, you can select welding mode or function mode by press the
parameters select/adjust knob (3).
Parameters select/adjust knob (3)
When locking the “SETING” interface, you can select welding mode: TIG LIFT, TIG HF
or MMA by turning the knob. Similarly, you can select function mode: PULSE, NO
PULSE or SPOT (Spot is only available in TIG HF welding mode) by turning the knob.
When unlocking the “SETING” interface, you can press the knob to select parameters,
such as welding current, Peak current, Base current, Pulse frequency and Pulse width.
Rotate it to adjust parameters’ value.
1. Screen
It will show all welding parameters, such as welding voltage, welding current and other parameters set.
2. SETTING button.
3. Parameters select/adjust knob.
4. Trigger mode selection
Press it to select 2T or 4T trigger mode.
Further Controls Explained
SETTING button (2)
Press it to lock “SETTING” interface and press again or wait for 2s to unlock. In “SETING” interface, you can
select welding mode or function mode by press the parameters select/adjust knob (3).
Parameters select/adjust knob (3)
When locking the “SETTING” interface, you can select welding mode: TIG LIFT, TIG HF or MMA by turning
the knob. Similarly, you can select function mode: PULSE, NO PULSE or SPOT (Spot is only available in TIG
HF welding mode) by turning the knob.
When unlocking the “SETTING” interface, you can press the knob to select parameters, such as welding
current, Peak current, Base current, Pulse frequency and Pulse width. Rotate it to adjust parameters’ value.
Summary of Contents for Evolution TS200DC
Page 27: ...27 Notes ...