12
2.1 MMA Display
INSTALLATION & OPERATION
8
§3.2.2 MMA display introduction
1. Welding mode key
: Press it to enter MMA welding mode.
2. Out waveform key
: Press it to select DC output or AC Square wave output.
3. Parameter A key
: Press it to select Hot start. Setting range: 0 - 10.
4. Parameter B key
: Press it to select Arc force. Setting range: 0 - 10.
5. Parameter adjust knob
: Rotate it to adjust welding current and value of Hot start
and Arc force.
6. Current display
: It displays welding current during welding operation, otherwise
show current selected.
7. Welding voltage display
: It displays welding voltage.
1. Welding mode key
Press it to enter MMA welding mode.
2. Out waveform key
Press it to select DC output or AC Square wave output.
3. Parameter A key
Press it to select Hot start. Setting range: 0 - 10.
4. Parameter B key
Press it to select Arc force. Setting range: 0 - 10.
5. Parameter adjust knob
Rotate it to adjust welding current and value of Hot start and Arc force.
6. Current display
It displays welding current during welding operation, otherwise show current selected.
7. Welding voltage display
It displays welding voltage.