3
Remove the juice strainer and the middle ring in order.
4
With water, clean the pomace cup, middle ring, juicing screen, and juice cup
successively.
Chapter 5: Safety indexes
As a class II electric appliance, this product needs no grounding device.
Chapter 6: Fault analysis and elimination
Fault
Possible cause
Elimination
After the power supply is
connected and the switch
is turned on, the product
does not run.
1. The middle ring is not
correctly installed.
2. The top cover is not
correctly installed.
3 The top cover contact has
fractured.
1. Install the middle ring correctly.
2. Install the top cover correctly.
3. Replace the top cover.
There is a bad smell from
the motor the first few
times using the product.
It is normal.
If the bad smell still exists after the product has been
used several times, have the product tested by a
designated service center.
Rated voltage
120V~
Rated power
500W
Rated frequency
60H z
Continual juicing time
≤
1 min.
Time interval
≥
2 min.