Wiring: 

Red  

12V (or 

  

switched 

12V) 

Black   G 

White   Not Used 

PN 18663 

PN 18663 Null Modem Cable—connects the modem to the CR23X, CR3000, CR800, CR2XX, CR1000 

or CR5000 RS-232 port 

(not compatible with the 21X, CR510, CR10X, or CR7 dataloggers). 

Summary of Contents for RavenXTV

Page 1: ...RavenXTV CDMA Sierra Wireless Cellular Modem Revision 9 11 C o p y r i g h t 2 0 0 6 2 0 1 1 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...eturn such products by surface carrier prepaid within the continental United States of America To all other locations Campbell will return such products best way CIP Port of Entry INCOTERM 2010 prepai...

Page 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Page 5: ...uirements for RavenXTV 2 4 2 Datalogger Site Equipment 3 4 3 Power Considerations 9 4 4 Automatic Provisioning Activation 9 5 Program the RavenXTV Modem 10 5 1 Using AceManager to Configure the Modem...

Page 6: ...Table of Contents ii Figures 4 2 1 Modem Interface Options 4 6 4 2 2 Antennas for Use with the Raven Modems 8 7 1 Device Port Configuration 20 7 2 AceManager status page showing communications with m...

Page 7: ...ynamic IP address is used with a service such as IP Manager Section 5 2 to translate domain name to a dynamic IP address so that the Raven can be contacted by name as if it had a static IP A Verizon a...

Page 8: ...ughput up to 80 kbps RS 232 Data Rates 1200 bps to 115 2 kbps Serial Interface RS 232 DB9 F Serial Protocols AT Commands PPP SLIP UDP IP TCP IP RF Antenna Connector 50 Ohm SMA female Input Current Ran...

Page 9: ...guration Utility Settings should be CS I O Mode SDC Address 7 RS 232 Mode Modem Baud Rate 115 2K or 9600 baud depending on datalogger model 8 data bits 1 stop bit no parity PN 18663 Null Modem Cable c...

Page 10: ...r Modem Wiring Red 12V or switched 12V Black G White Not Used PN 18663 PN 18663 Null Modem Cable connects the modem to the CR23X CR3000 CR800 CR2XX CR1000 or CR5000 RS 232 port not compatible with the...

Page 11: ...cable provided with the SC105 SC105 Settings CS I O Mode SDC Address 7 RS 232 Mode Modem Baud Rate 115 2K or 9600 baud depending on datalogger model 8 data bits 1 stop bit no parity SC105 interface c...

Page 12: ...Red 12V or switched 12V Black G White Not Used 10873 serial cable provided with the SC932A SC932A interface connects the modem to the CS I O port recommended for dataloggers with the Mixed Array Oper...

Page 13: ...onal antenna This antenna is dual band covering both the 800 MHz and 1 9 GHz bands and is strongly recommended where cellular coverage is strong The 18285 includes a mount u bolt assembly for attachin...

Page 14: ...less Cellular Modem PN 20679 Omni Directional Antenna PN 18285 1 dBd Omni Directional Antenna PN 14454 9dBd Directional Yagi Antenna PN 21831 Half Wave Dipole Whip Antenna FIGURE 4 2 2 Antennas for Us...

Page 15: ...han in the field NOTE One of the special features of your RavenXTV is the ability to activate itself automatically When you first power on the RavenXTV it will check to see if it has been activated wi...

Page 16: ...pbellsci com downloads Indicator Lights When your RavenXTV is connected to power and an antenna there is a specific pattern to the lights to indicate its operation mode Network Indicates a successful...

Page 17: ...aloggers The recommended way to change the settings is to send a template file to the modem using the AceManager utility The AceManager utility is on the CD that ships with the Raven modem and is also...

Page 18: ...in the Configuration Panel to open the connection options dialogue box Select PPP and the COM port the modem is connected to Do not change the Password the default password is 12345 Click OK to conti...

Page 19: ...screens show the settings for the Miscellaneous and Serial settings after the template file has been loaded Change AT Verbose Mode to Numeric for use with CR10 X CR510 and CR23X dataloggers Click the...

Page 20: ...mic IP address to a fully qualified domain name so you can contact your Raven by name as if it had a static IP If the Raven is configured for Dynamic IP when the Raven first connects to the Internet i...

Page 21: ...in spaces Must be no longer than 20 characters total Click the Write icon to save the changes Click the Reset icon to restart the modem Click the Disconnect icon to terminate communications with the m...

Page 22: ...ros are not entered in the Internet IP Address e g 070 218 074 247 is entered as 70 218 74 247 For a Dynamic IP using Sierra Wireless s IP Manager enter the internet IP address as xxxx yyyy 3001 where...

Page 23: ...RavenXTV CDMA Sierra Wireless Cellular Modem Uncheck PakBus Port Always Open Enter PakBus address that has been set in the datalogger default is 1 change the address using DevConfig 17...

Page 24: ...TV this should be a CDMA 1xRTT EVDO account f If you have a Static IP account verify the Static IP Address Preceding zeros in the IP address are not entered in LoggerNet PC400 g If you have a Dynamic...

Page 25: ...dataloggers e g CR1000 If the modem answers but you do not get a connection to the datalogger 1 Check your connection to the datalogger a a An SC932A or SC105 interface is required to connect the mode...

Page 26: ...2 Mode Modem Baud Rate 115 2K or 9600 baud depending on datalogger model 8 data bits 1 stop bit no parity b Make sure the modem is connected to the DCE Device connector on the SC932A or the Modem conn...

Page 27: ...OK Go to the Status group and note the Host Serial Bytes Sent and Host Serial Bytes Received values Figure 7 2 Try connecting with the datalogger using LoggerNet PC400 If a connection cannot be establ...

Page 28: ...RavenXTV CDMA Sierra Wireless Cellular Modem FIGURE 7 2 AceManager status page showing communications with modem 22...

Page 29: ...ebsite http www campbellsci com downloads The procedure for sending the template files is described in Section 5 3 When the template files are not available AceManager can be used to change the settin...

Page 30: ...igured to match a valid datalogger baud rate For a CR10X 9600 8N1 and for a CR1000 115200 8N1 Q Serial Port Flow Control This should be set to None V AT Verbose Mode Set this to Verbose for CR800 CR10...

Page 31: ...Appendix A AceManager Setup without Template File S0 TCP Auto Answer Set to On TCPT TCP Idle Timeout Set to a reasonable value like 2 min A 3...

Page 32: ...Appendix A AceManager Setup without Template File A 4 This is a blank page...

Page 33: ...talogger and allows concurrent communications between networked dataloggers and LoggerNet The default datalogger port number for PakBus TCP communications is 6785 The datalogger will also respond to p...

Page 34: ...PPP Datalogger Settings Using the Device Configuration Utility configure the following setting on the TCP IP tab Config Port Used RS232 IP Address 0 0 0 0 Modem Dial String PPP Modem Dial Response CON...

Page 35: ...Modem for PPP Using the Device Configuration Utility select the Net Services tab The PakBus TCP Service Port default is 6785 This is the Port number that will follow the IP address for LoggerNet to co...

Page 36: ...Using the Device Configuration Utility fix the RS232 Baud Rate to 115200 Fixed from the Port Settings tab LoggerNet Settings Enter the IP address of the Raven and the PakBus TCP Service Port number of...

Page 37: ...smtp gmail com UserName set to the gmail account user name Password the one you established at gmail Gmail requires Transport Layer Security TLS to connect to their mail server You must go into the Se...

Page 38: ...ToAddr datalogger hotmail com 4355551234 vtext com Const FromAddr gmailaccount gmail com Const Subject Email Message Test Const Attach Const CRLF CHR 13 CHR 10 Public Result as String 100 Public Alar...