Raven XT-Telus CDMA Sierra Wireless Cellular Modem
4. Configuration
4.1 Base Station Requirements for Raven XT-Telus
PC running Campbell Scientifics’ LoggerNet or PC400 software, with access
to the internet.
4.2 Datalogger Site Equipment
x
Raven modem with power cable (included with modem).
x
Datalogger—21X, CR510, CR10(X), CR23X, CR7, CR1000, CR5000,
CR3000, CR800.
x
SC105 or SC932A Interface—connects the modem to the 21X, CR510,
CR10(X), CR7, or other dataloggers’ CS I/O port.
x
The SC105 must be configured for use with the modem using the Device
Configuration Utility. Settings should be:
CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity
x
PN L18663 Null Modem Cable—connects the modem to the CR23X,
CR3000, CR800, CR2XX, CR1000 or CR5000 RS-232 port.
If you have a black SC12 cable that is not Rev 1 or newer (as
indicated on cable), it is a CS I/O cable only and will not work
for RS-232. Connect the black SC12 cable between the
datalogger and the SC932A. Use a 9-pin serial cable or a blue
ribbon cable between the phone and the SC932A.
NOTE
4