background image

                      

Sierra Products, Inc. 5061 Brooks St., Ste B Montclair, CA 91763

 

       P/N 140790r2 03/2007

SIERRA UV36OFP 

OUTDOOR GAS 

FIREPLACE 

INSTALLATION AND OPERATING INSTRUCTIONS 

WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.

WARNING: This gas fireplace is approved for outdoor installation only.

DESIGN CERTIFIED TO CSA 4.96 U.S. (2

nd

 ED.)

OUTDOOR GAS FIREPLACE

 -

 

Do not store gasoline or other flammable vapors and liquids in the

   vicinity of this or any other appliance.

 -

 WHAT TO DO IF YOU SMELL GAS

C

 

Do not try to light any appliance.

C

 

Do not touch any electrical switch; do not use any phone

   in your building.

 

C

 Immediately call your gas supplier from a neighbor’s phone.

   Follow the  gas supplier’s instructions.

C

 If you cannot reach your gas supplier, call the fire department.

 -

 Installation and service must be performed by a qualified installer, 

   service agency, or the gas supplier.

Save this manual for future reference.

Summary of Contents for UV360FP

Page 1: ...TO CSA 4 96 U S 2nd ED OUTDOOR GAS FIREPLACE Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS C Do not try to ligh...

Page 2: ...ff fireplace and call a qualified service person Note During initial operation slight smoking will occur due to log curing and fireplace burning manufacturing residues 8 Avoid operating fireplace in h...

Page 3: ...re space is limited or at a premium Check local codes for any restrictions Projected installations can extend any distance into the room A projection may be ideal for a new addition on an existing fin...

Page 4: ...MOTE CONTROL UNIT Note Be sure to read the instructions included with remote control unit prior to installing 1 Install the remote control unit into remote control bracket and using 2 8 Phillips screw...

Page 5: ...er than ceramic or any combustible material other than wood flooring the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace If a raised platform...

Page 6: ...11 and 14 inches of water Of you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in figure 12 Pointing the vent...

Page 7: ...s in excess of psig will damage the fireplace gas regulator 2 Cap off the open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by either using compressed air...

Page 8: ...soft bristle brush A visual inspection of the pilot burner and main burner flame should be performed to verify proper operation refer to operating instructions for proper adjustment Care should be ta...

Page 9: ...ce if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater...

Page 10: ...185 4 1 SS Optional Trim left hand 200761 14 2 Fireplace Screen 110388 5 1 SS Optional right hand 200762 15 2 Fireplace Screen Rod 200746 6 1 Refractory Left Side 200749 16 1 Remote Control MV Assy 10...

Page 11: ...horized service center SPI may require the consumer to supply reasonable proof of the stoves purchase date This warranty is in lieu of any other express warranty Any implied warranties including but n...

Reviews: