background image

7

Figure 14 - Accessing burner assembly

Figure 15 - Attaching Flexible Gas Lines Together

WARNING: Test all gas piping and connections for
leaks after installing or servicing. Correct all leaks
at once.

WARNING: Never use an open flame to check for a
leak. Apply a mixture of liquid soap and water to
all joints. Bubbles forming show a leak. Correct all
leaks at once.

Figure 16 - Manual Shutoff Valve

Figure 17 - Checking Gas Joints

3. Remove the gas line cover plate from the fireplace’s
outer surround at the location to be used. Remove
insulation from inside the gas line conduit sleeve. Run
gas line through until the regulator can be reached.

4. Apply pipe sealant lightly to male threads of gas
connector attached to flexible gas line (see figure 15).
Connect flexible gas line to flexible gas line attached to
gas inlet gas valve of fireplace. (Fig 

14

).

5. Check all gas connections for leaks. See 

Checking

Gas Connections,

 below.

6. Place log base assembly completely  into the
fireplace.

CHECKING GAS CONNECTIONS

Pressure Testing Gas Supply Piping System
Test Pressures in Excess of ½ PSIG

1.  Disconnect the fireplace and its individual manual
shutoff valve from gas supply piping system. Pressures
in excess of ½ psig will damage the fireplace gas
regulator.
2. Cap off the open end of gas pipe where manual
shutoff valve was connected.
3. Pressurize supply piping system by either using
compressed air or opening main gas valve located on or
near gas meter.
4. Check all joints of gas supply piping system. Apply a
mixture of liquid soap and water to gas joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Re-connect fireplace and manual shutoff valve to
gas supply. Check re-connected fittings for leaks.

Test Pressures Equal to or Less Than ½ PSIG

1. Close manual shutoff valve (see Figure 

16

)

2. Pressurize supply piping system by either using
compressed air or opening propane supply tank valve.

3. Check all joints from propane supply tank (see fig

24

). Apply a mixture of liquid soap and water to gas

joints. Bubbles forming show a leak.
4. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1. Open manual shutoff valve (see figure 

16

).

2. Open propane supply tank valve.
3. Make sure control knob of fireplace is in 

OFF

position.

4. Check all joints from manual shutoff valve to gas
valve (see Figure 17). Apply a mixture of liquid soap and
water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light the fireplace (see 

Operating Instructions

).

Check all other internal joints for leaks.

7. Turn off the fireplace (see 

Operating Instructions

).

Summary of Contents for UV360FP

Page 1: ...TO CSA 4 96 U S 2nd ED OUTDOOR GAS FIREPLACE Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS C Do not try to ligh...

Page 2: ...ff fireplace and call a qualified service person Note During initial operation slight smoking will occur due to log curing and fireplace burning manufacturing residues 8 Avoid operating fireplace in h...

Page 3: ...re space is limited or at a premium Check local codes for any restrictions Projected installations can extend any distance into the room A projection may be ideal for a new addition on an existing fin...

Page 4: ...MOTE CONTROL UNIT Note Be sure to read the instructions included with remote control unit prior to installing 1 Install the remote control unit into remote control bracket and using 2 8 Phillips screw...

Page 5: ...er than ceramic or any combustible material other than wood flooring the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace If a raised platform...

Page 6: ...11 and 14 inches of water Of you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in figure 12 Pointing the vent...

Page 7: ...s in excess of psig will damage the fireplace gas regulator 2 Cap off the open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by either using compressed air...

Page 8: ...soft bristle brush A visual inspection of the pilot burner and main burner flame should be performed to verify proper operation refer to operating instructions for proper adjustment Care should be ta...

Page 9: ...ce if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater...

Page 10: ...185 4 1 SS Optional Trim left hand 200761 14 2 Fireplace Screen 110388 5 1 SS Optional right hand 200762 15 2 Fireplace Screen Rod 200746 6 1 Refractory Left Side 200749 16 1 Remote Control MV Assy 10...

Page 11: ...horized service center SPI may require the consumer to supply reasonable proof of the stoves purchase date This warranty is in lieu of any other express warranty Any implied warranties including but n...

Reviews: