background image

 Instruction Manual

Page:

2050/2060 Gas Monitors (5/04)

In all cases SMC’s responsibility and liability under this
warranty shall be limited to the cost of the equipment.  The
purchaser must obtain shipping instructions for the prepaid
return of any item under this warranty provision and com-
pliance with such instruction shall be a condition of this
warranty.

Except for the express warranty stated above, SMC disclaims
all warranties with regard to the products sold hereunder
including all implied warranties of merchantability and fit-
ness and the express warranties stated herein are in lieu of all
obligations or liabilities on the part of SMC for damages
including but not limited to consequential damages arising
out of/or in connection with the use or performance of the
product.

8.0  SPECIFICATIONS

Indicators:

Green LED for Monitor “ON”/Safe
Red LED for Alarm

Sensor Type:

Solid-state metal oxide semiconduc-
tor

Alarm Setpoint::

2050 Series

100 ppm NH

3

2060 Series

R11

500 ppm

R12

500 ppm

R22

50 ppm

R113

 100 ppm

R123

70 ppm

R134a

50 ppm

R141b

40 ppm

R142b

40 ppm

R500

40 ppm

R502

70 ppm

User adjustable with calibration over
range of 50 to 500 ppm

Calibration Gas:
    2050 Series

80  ppm Hydrogen (H

2

)

    2060 Series

150 ppm Carbon Monoxide (CO)

Power:

9 VDC, 250 mA

Signal Output::
   2050-00/2060-00

Nominal 5 volt DC, source 25 mA.
SAFE and ALARM Signals
0.5 AMP dry contact, 100 VDC, 130
VAC

Response Time:

Less than 90 seconds

Operating Temperature Range:

-4

o

 to 158

o

F (-20

o

 to 70

o

C)

Enclosure Material:

Polystyrene

Size:

5.6 x 3.1 x 2.1 in.

(14.2 x 7.9 x 5.3 cm)

Weight:

0.3 lb (0.15 Kg)

9.0  ACCESSORIES AND REPLACEMENT PARTS

Alarm Panels

Model 2102-00 Alarm Panel - 2 channel
Model 2102-01 Alarm Panel - 2 channel with audible

Calibration Accessories

1200-26

Gas Sensor Calibrator w/2 gas cylinders
(specify gas type/conc)

1290-10

Gas Cylinder - Carbon Monoxide 150 PPM

1290-11

Gas Cylinder - Hydrogen 80 PPM

Replacement parts

SPF22073

Sensor for 2050-XX

SPF22074

Sensor for 2060-XX

10.0 LIMITED WARRANTY

SIERRA MONITOR CORPORATION warrants its products
to be free from defects in workmanship or material under
normal use and service for two year after date of shipment.
SMC will repair or replace without charge any equipment
found to be defective during the warranty period.  Final
determination of the nature and responsibility for defective
or damaged equipment will be made by SMC personnel.

All warranties hereunder are contingent upon proper use in
the application for which the product was intended and do
not cover products which have been modified or repaired
without SMC approval or which have been subjected to
accident, improper maintenance, installation or application,
or on which original  identification marks have been re-
moved or altered.  This Limited Warranty also will not apply
to interconnecting cables or wires, consumables (ie. calibra-
tion gases, batteries), nor to any damage resulting from bat-
tery leakage.

11

Summary of Contents for 2050-00 Applicability & effectivity

Page 1: ...GAS MONITORS MODELS 2050 00 2050 10 MODELS 2060 00 2060 10 ...

Page 2: ...nitor com GAS MONITORS MODELS 2050 00 2050 10 MODELS 2060 00 2060 10 APPLICABILITY EFFECTIVITY This manual provides instructions for the following Sierra Monitor products Model Description 2050 00 Ammonia Gas Monitor 2060 00 Halocarbon Gas Monitor The instructions are effective for the above models as of January 1 2004 Instruction Manual Part Number T10013 Rev C ...

Page 3: ...Alarms 4 3 3 Outputs 4 4 ALARM CALIBRATION 5 4 1 FactoryAlarm Calibration 5 4 2 Frequency ofAlarm Calibration Check 5 4 3 Alarm Calibration Check Process 5 4 4 Equipment Required 6 4 5 Alarm Calibration Procedure 6 5 SERVICE 5 1 Sensor Replacement 7 6 INSTALLATION 8 6 1GasSensorModuleLocations 8 6 2 Mounting 8 6 3 Wiring 8 6 4PowerSupply 8 6 5AlarmDevices 8 7 ALARM CONFIGURATION 10 8 SPECIFICATION...

Page 4: ...onitors The models can be config ured with a 0 5 amp dry contact relay The monitors are housed in a polystyrene enclosure that is suit able for installation in freezer re frigerator or other applications Test connections and adjustment controls are located on the out side of the enclosure and are eas ily used even when the operator is wearing hand protection The Model 2050 Ammonia moni tor has a f...

Page 5: ...operate the monitor except the DC input power is contained in a compact unit There are no pumps filters or chemical cells to replace or maintain Except for periodic calibra tion to verify the alarm setting no attention is required after installation The user may adjust the alarm level by applying a different calibration gas concentration A sensor self check feature will flash the alarms on and off...

Page 6: ...n Terminal positions on the electronics board are as follows 2 2 3 Start up Operation To begin operation of the Gas Sensor Module provide 9 24 VDC from a regulated power supply such as one of the Sierra Monitor Alarm Panels 2102 XX Each time the sensor mod ule is powered up it will perform a warm up for 2 60 minutes During warm up the monitor will first cycle through safe alarm safe condition at o...

Page 7: ...ed light once the warm up time is completed indicat ing the presence of gas at or above the pre set alarm limit Table 2 1 Buzzer Relay Relay Fail Safe On Closed Open Trouble Alarm Interrupted contact closure and red green vi sual indication once the warm up time is com pleted after unit has been in operation indicat ing either a failed sensor or calibration problems Buzzer Relay Relay Fail Safe On...

Page 8: ...ing periods of extreme humidity and temperature changes The monitor should have operated con tinuously uninterrupted for at least 24 hours prior to calibration adjustment 4 3AlarmCalibrationCheckProcess Theoutputsignalofthegassensormoduleiscalibrated using a calibration gas mixture containing a known concentrationofthegasofinterestandabalanceofair orusingasubstitutegas Theconcentrationofthespan ga...

Page 9: ...onitor in operation expose the sensor to a sample of calibration gas Apply calibration gasdirectlytothesensorinsuringthatthedelivery cuplooselycoversthesensor Use80PPMH2 for the Model 2050 and 150 PPM CO for the Model 2060 3 TheredLEDonthefaceofthemonitorshouldturn on Ifthealarmoccurswithin18 20secondsand stops within one minute of the removal of the cali bration gas the monitor is in calibration ...

Page 10: ...or 1 Confirm that the system power has been removed Figure 5 1 Model 2050 2060 Electronics Board Connections 2 Remove the cover from the main enclosure 3 Unplug the sensor connector on the lower right hand corner of the electronics board 4 Unscrewthesensorassemblyfromtheendofthe enclosure 5 Reversetheprecedingstepstoinstallthenewsen sorassembly 6 Restore power and allow a minimum of 24 hours for s...

Page 11: ...rs of the housing to mount the monitor to a wall The installation must meed any hazardous envi ronmental codes for AC DC electrical instrumenta tion 6 3 Wiring Interconnect wiring from the controller to the module is by 4 conductor 22 AWG or lower AWG cable conduit as necessary Shielding is not required For installations where the distance from the con troller to the sensor is greater than 500 fee...

Page 12: ...Instruction Manual Page 2050 2060 Gas Monitors 5 04 Figure 6 1 InterconnectWiring Table 9 ...

Page 13: ...st for 20X N A N A TB1 1 TB1 2 TB2 1 TB2 3 DCV To Model 2102 Terminal J5 2 or J6 2 0 DC To Model 2102 Terminal J5 3 or J6 3 Safe To Model 2102 Terminal J5 1 or J6 1 Alarm To Model 2102 Terminal J5 4 or J6 4 Not Used TB2 3 NO Output Terminals TB2 2 Configuration Jum pers Configuration Jum pers Model 20X or 200X Configured w ith Alarm Relay Output W iring Terminations Normally Energized Install Jump...

Page 14: ...s 0 5 AMP dry contact 100 VDC 130 V AC Response Time Less than 90 seconds Operating Temperature Range 4o to 158o F 20o to 70o C Enclosure Material Polystyrene Size 5 6x3 1x2 1in 14 2x7 9x5 3cm Weight 0 3lb 0 15Kg 9 0 ACCESSORIES AND REPLACEMENT PARTS Alarm Panels Model 2102 00 Alarm Panel 2 channel Model 2102 01 Alarm Panel 2 channel with audible CalibrationAccessories 1200 26 Gas Sensor Calibrato...

Reviews: