Sierra Flame Newcomb 36 Installation And Operating Instructions Manual Download Page 5

Page 5 of 56   

Do not use this appliance if any part has 
been under water. Immediately call a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water. 

Ne pas utiliser cet appareil s’il a été plongé, 
meme partiellement, dans l’eau. Appeler un 
technician qualifié pour inspecter l’appareil et 
remplacer toute partie du système de 
commande et toute commande qui a été 
plongée dans l’eau. 

Toddlers, young children and others may be 
susceptible to accidental contact burns. A 
physical barrier is recommended if there are 
at risk individuals in the house. To restrict 
access to a fireplace or stove install an 
adjustable safety gate to keep toddlers, 
young children and at risk individuals out of 
the room and away from hot surfaces. 
Any safety screen or guard removed for 
servicing an appliance must be replaced 
prior to operating the appliance. 
Installation and repair should be done by a 
qualified service person.  The appliance 
should be inspected before use and at least 
annually by a professional service person.  
More frequent cleaning may be required due 
to excessive lint from carpeting, bedding 
material, et cetera.  It is imperative that 
control compartments, burners and 
circulating air passageways of the appliance 
be kept clean. 

Les tout-petits, les jeunes enfants et d'autres 
peuvent être sensibles aux brûlures par 
contact accidentel. Une barrière physique est 
recommandé s'il ya des personnes à risque 
dans la maison. Pour restreindre l'accès à une 
cheminée ou un poêle installer une barrière de 
sécurité réglable pour garder les tout-petits, 
les jeunes enfants et les personnes à risque de 
la salle et à l'écart des surfaces chaudes. 
Tout écran ou grille de protection pour 
l'entretien d'un appareil doit être remplacé 
avant de faire fonctionner l'appareil. 
Installation et réparation doit être effectuée par 
un technicien qualifié. L'appareil doit être 
inspecté avant son utilisation et au moins 
annuellement par un technicien qualifié. Un 
nettoyage plus fréquent peut être nécessaire 
en raison de peluches provenant des tapis, 
literie, etc. Il est impératif que les 
compartiments de contrôle, les brûleurs et les 
conduits d'air de l'appareil soient gardés 
propres.

 

This fireplace is a vented product. This 
fireplace must be properly installed by a 
qualified service person. The glass door 
must be properly seated and sealed. If this 
unit is not properly installed by a qualified 
service person with the glass door properly 
seated and sealed gas leakage can occur. 

Ce foyer est un produit ventilé. Ce foyer doit 
être correctement installé par un technicien 
qualifié. La porte en verre doivent être placés 
correctement et scellé. Si cet appareil n'est 
pas correctement installé par un technicien 
qualifié avec la porte en verre bien en place et 
des fuites de gaz scellés peuvent se produire. 

Caution: Label all wires prior to 
disconnection when servicing controls. 
Wiring errors can cause improper and 
dangerous operation. 

Attention : Au moment de l’entretien des 
commandes, étiquetez tous les fils avant de 
les débrancher. Des erreurs de câblage 
peuvent entraîner un fonctionnement 
inadéquate et dangereux. 

Verify proper operation after servicing 

S’assurer que l’appareil fonctionne 
adéquatement une fois l’entretien terminé 

If this appliance is installed on carpeting, 
vinyl tile or other combustible material other 
than wood flooring, the appliance shall be 
installed on a metal or wood panel extending 
the full width and depth. 

Si cet appareil est installé sur un tapis, 
carreaux de vinyle ou autre matériau 
combustible autre qu'un plancher de bois, 
l'appareil doit être installé sur un panneau de 
métal ou de bois se prolongeant sur toute la 
largeur et la profondeur. 

Summary of Contents for Newcomb 36

Page 1: ...ion and service must be performed by a qualified installer service agency or gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damag...

Page 2: ...l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Une mauvaise installation de r glage la modification de services ou de...

Page 3: ...allation 22 3 3 3 Thermostat Wall Switch or Digital On Off Remote 22 24 3 3 4 Direct Vent Information 24 32 3 3 5 Glass Installation 33 3 3 6 Door Installation 34 3 3 7 Initial Firing 35 3 3 8 Manifol...

Page 4: ...cal shock and carbon monoxide poisoning AVERTISSEMENT Lisez ce manuel attentivement et compl tement avant d essayer de monter utiliser ou entretenir ce foyer Suire les instructions pour assurer une bo...

Page 5: ...en d un appareil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au...

Page 6: ...ER VOLET DE L AIR OPEN 1 8 min 3 175mm CONTROL VALVE TYPE TYPE DE SOUPAPE Skytech AF 40004 Robertshaw VENTING VACUATION 2 ply aluminum vent Duravent Metal Fab Venting or Security Venting FAN VENTILATE...

Page 7: ...licensed gas fitter Failure to comply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet apparei...

Page 8: ...s will activate the setup mode Setup mode can also be activated by pressing the FLAME REAR and PROG TIME buttons simultaneously for 5 seconds The control will exit setup mode if no button is pressed f...

Page 9: ...trol to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon wil...

Page 10: ...the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single...

Page 11: ...ue serving a separate solid fuel burning appliance Cet appareil ne doit pas tre raccord une chemin e desservant un autre appareil br lant des combustibles solides The appliance area must be kept clear...

Page 12: ...toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the applia...

Page 13: ...tempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace an...

Page 14: ...provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifi et remplacez toute partie du sy...

Page 15: ...this label 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Controls are accessed by opening the bottom louver 5 Push in gas control knob slightly and turn...

Page 16: ...upez l alimentation lectrique de l appareil 4 Les contr les sont accessibles par l ouverture de la persienne inf rieure 5 Poussez le bouton de contr le du gaz et tourner vers la droite pour OFF 6 Atte...

Page 17: ...rounding Instructions Instructions la terre lectrique This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a proper...

Page 18: ...Page 18 of 56 Figure 2...

Page 19: ...s components as this will damage the valve Ne pas communiquer 120 VAC la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance careful...

Page 20: ...40 TO INTERNAL CEILING COMBUSTIBLE MATERIAL 2 TO INTERNAL SIDE COMBUSTIBLES 6 TO EXTERNAL SIDE WALL 36 MINIMUM CEILING HEIGHT FROM TOP OF UNIT 40 MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE 12 DEEP SE...

Page 21: ...ur d terminer la taille permise manteau repose sur l l vation au dessus de la garniture unit s sup rieures CAU TION ATTENTION When using paint or lacquer to finish the mantel such paint or lacquer mus...

Page 22: ...inet d arr t doit tre d connect e de la canalisation de gaz pendant tout test de pression du syst me des pressions sup rieures 1 2 psi 3 45 kPa Install the gas line as follows The appliance shall be i...

Page 23: ...mostat Soyez conscient que la longueur du c ble augmente la probabilit de la tension de fonctionnement ad quat diminue TABLE 1 THERMOSTAT WIRE INFORMATION WIRE SIZE MAX WIRE LENGTH AWG mm ft m 22 0 6...

Page 24: ...sur le c t de l chappement et num r s 7 flex vent sur le c t d admission d air ou peut tre utilis avec la s curit d vacuation ou de Dura Vent 4 x 5 6 8 avec l utilisation d adaptateurs Dura Vent part...

Page 25: ...vent system consists of Dura Vent adapter Part 0924N3 45 off the unit 34 10363 mm vertical length off the 45 pipe 3 90 degree elbows 12 3658 mm maximum horizontal length Wall thimble part IMC1082A Ho...

Page 26: ...horizontal length Wall thimble part IMC1082A Horizontal termination cap 4DHT The maximum vertical system consists of Metal Fab adapter Part 4DDA 45 off the unit Up to 34 10363 mm of vertical length F...

Page 27: ...ontal Vertical Venting Sample Chart Vertical Venting Sample Chart Maximum length 34 10363mm Maximum total H offset 12 3658mm H Max V Min H H1 H2 Max A 2 3 5 B 8 5 12 V Min H1 H2 H3 Max A 3 5 B 5 12 H...

Page 28: ...rvicing be sure to follow above instructions for resealing venting when reconnecting to system FIGURE 7 VENT RESTRICTOR INSTALLATION VENT RESTRICTOR To fasten the Restrictor Plate to the ceiling of th...

Page 29: ...al screws for Z Flex installations an Sierra Flame s termination part IMC1070A or IMC1070B shall be used and when using Dura Vent or Security Venting a Dura Vent termination part P574 shall be used If...

Page 30: ...d frame as shown in the diagram below NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STATE PROVINCE TO PROVINCE TOUJOURS v rifier les codes locaux a...

Page 31: ...f 2 from any wall To prevent water seepage install the flashing with upper portion under the roofing material and the lower portion over the roofing material Note Do not fasten down until the final ad...

Page 32: ...ty M Clearance under veranda 12 in 30 cm porch deck or balcony 0 0 3 3 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223...

Page 33: ...la porte Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to...

Page 34: ...fortement recommand que vous contactez une personne qualifi e Retirez les morceaux n oubliez pas de porter des gants et enlever la porte Voir la liste des pi ces de rechange la fin du manuel vous aure...

Page 35: ...y condense and fog the glass and the flames may be partially blue After a few minutes the moisture will disappear and the flames will become yellow Visually check the flame after warm up 3 3 8 MANIFOL...

Page 36: ...onnement correct de l appareil Une accumulation de carbone de levage flammes ou de toute d faillance due une mauvaise a ration d ajustement lors de l installation n est pas couvert par la garantie d u...

Page 37: ...lus de 2000 pieds 610m L entr e des appareils devrait tre r duite de 4 pour chaque 1000 pieds suppl mentaires 305m au dessus du niveau des mers Pour les tats Unis de taux de l unit de niveau de la mer...

Page 38: ...all Le ventilateur est fix avec des aimants pour la facilit d installation et peut tre retir de la paroi lat rale 4 Once removed from the wall the fan will slide out through the opening Une fois retir...

Page 39: ...AUTION ATTENTION TURN THE MAIN GAS POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSI...

Page 40: ...ity Soigneusement incliner la valve travers l ouverture et de sortir de la chambre de combustion pour l accessibilit 4 Replace valve in reverse order from steps 3 through 1 Remplacer la vanne dans l o...

Page 41: ...liance regularly Annual service An annual service call should take between 1 2 hours Start by disassembling the unit take off the door and remove all the embers burner and logs Clean fan with a vacuum...

Page 42: ...iance and disconnect the gas line from the valve to the main orifice D brancher la conduite de gaz l appareil et d branchez la conduite de gaz de la vanne l orifice principal 5 Remove the screws holdi...

Page 43: ...depress control knob II Pilot will not stay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge...

Page 44: ...he millivolt meter The pilot flame may not be high enough for the flame to properly engulf the thermopile If so adjust and reset If voltage is still insufficient replace thermopile 9 Wall switch therm...

Page 45: ...ilot will not stay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermoco...

Page 46: ...lacement V Flame burns blue and lifts off burner 1 Insufficient combustion air being supplied 1 Ensure that no foreign material blocks air inlets Ensure the vent is adequate 2 Manifold pressure set to...

Page 47: ...5 44 N A Gas Valve Robertshaw 9A0A68A6A CSA UL Piezo Igniter R S only 1244 46 CSA Rock Glass Kit RGKST21 N A Intermittent Pilot Remote Control Valve Parts Description Part Pilot Assembly Intermittent...

Page 48: ...y not be extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in accordance with the...

Page 49: ...ts de Sierra Flame sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Le br leur et la valve sont des essais d ta...

Page 50: ...emi re ann e Sierra Flame peut sa discr tion se d charger de toutes obligations l gard de cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fectueuse...

Page 51: ...Page 51 of 56 8 0 LABEL INFORMATION...

Page 52: ...emove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et doit...

Page 53: ...Page 53 of 56 APPENDIX A AMERICAN FLAME VALVE INFORMATION...

Page 54: ...Page 54 of 56 APPENDIX A Continued...

Page 55: ...in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off T...

Page 56: ...Page 56 of 56 APPENDIX A Continued AF 4000 Wiring Diagram Sierra Flame 1503 7088 18th Ave Burnaby BC V3N 0A2...

Reviews: