Page 6 of 45
1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM
NATURAL GAS (NG)
INPUT: Hi
19,000 Btu/hr (5.57 kW)
INPUT: Lo
13,500 Btu/hr (3.96 kW)
MANIFOLD PRESSURE: Hi
COLLECTEUR DE PRESSION: FORT
3.5” w.c. (0.87 kPa)
HI-LO BURN FLO SET SCREW
SALUT-LO GRAVER FLUX VIS
# 50
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
Minimum: 5.0” w.c. (1.2 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
ORIFICE SIZE: @ 0-4500
’
FORMAT D'ORIFICE:
# 45 DMS
AIR SHUTTER
VOLET DE L’AIR
OPEN 1
/8”min
(3.175mm)
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
Skytech AF-40004
VENTING
ÉVACUATION
Existing 5” B-Vent venting intake air
2-ply aluminum flexpipe exhaust
FAN
VENTILATEUR
Variable Speed (115 Volt)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
WARNING
This fireplace will only operate when the fan is on. (see page 29)
Ce foyer ne fonctionne que lorsque le ventilateur est en marche. (voir page 29)