3.3.3  DIRECT VENT INFORMATION CONT 
 
VENTING INSTALLATION INSTRUCTIONS  

1/. 

Remove existing fireplace leaving 5’’ certified B-Vent pipe in place 

 
2/.  Make sure B-Vent pipe is properly secured  
 
3/. Remove the 1st 1’–4’ section of the B-Vent pipe from the bottom of the 5’’ certified B-Vent piping 
 
4/.  Add the certified adaptor (Ecco part # 5DHC)  to the bottom of the pipe and lock it into place  
 
5/.  Go to roof and remove existing chimney cap  
 
6/.  Slide continuous 

50’ length of 3’’ 2 ply certified flex pipe with spacers provided (1 for every 3’ of pipe) down  

the  center of the 5’’ certified B-Vent pipe  
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The spacers are to hold the 3’’ flexpipe  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

centered in both the 5’’ flexpipe and the  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5’’ B-Vent pipe 

 
 
 
 
 
 
 
 
7/. 

Go back down to fireplace site and make sure 3’’ certified flex pipe is protruding from bottom of 5’’ cetified 

B-Vent pipe 
 
8/. 

Slide 1’ – 4’ length (as required) of 5’’ certified flexpipe over the adaptor and 3’’ certified flexpipe . Seal join 

with high temperature red silicon then secure to adaptor with 3 self tapping screws 
 
9/. Pull 3’’ certified flexpipe down over 3’’ collar on top of fireplace. Seal join with high temperature milpak  
 then secure to collar with 3 self tapping screws  
 
10/.Once 3’’ pipe is securely joined to fireplace collar, repeat the procedure with the 5’’ certified flexpipe. Make  
 sure join is sealed with high temperature red silicon and pipe is secured in place with 3 self tapping screws 
 
11/.Go back up to roof and 

cut off excess 3’’ certified flexpipe. Slide 3’’ over collar of certified termination cap 

(part #  1032) and secure to the cap with 3 self tapping screws  
 
12/.

Push termination cap down so 5’’ collar on cap slides over 5’’ certified B-Vent pipe. Secure in place with 3  

 self tapping screws  

 

NOT

E

 

ONLY CERTIFIED VENTING MATERIALS MAY BE USED IN INSTALLATION. 
 
NO SILICON SEALANT IS REQUIRED ON THE JOINS ON THE TERMINATION CAP 
 
MINIMUM CLEARANCE OF 1’’ MUST BE MAINTAINED ALL AROUND THE 5’’ B-VENT 
PIPE.

 

Summary of Contents for BRADLEY-36-NG

Page 1: ...d by a qualified installer service agency or gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assis...

Page 2: ...re assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Une mauvaise installation de r glage la modification de services ou de maintenance peut caus...

Page 3: ...e Installation 19 3 3 3 Direct Vent Information 20 23 3 3 4 Rock Glass Installation 23 24 3 3 5 Door Installation and Safety Screen 24 26 3 3 6 Initial Firing 26 27 3 3 7 Manifold Pressure 27 3 3 8 Pr...

Page 4: ...ent et compl tement avant d essayer de monter utiliser ou entretenir ce foyer Suire les instructions pour assurer une bonne installation Risque de dommages ou de blessures si l appareil n est pas inst...

Page 5: ...Un nettoyage plus fr quent peut tre n cessaire en raison de peluches provenant des tapis literie etc Il est imp ratif que les compartiments de contr le les br leurs et les conduits d air de l appareil...

Page 6: ...RMAT D ORIFICE 45 DMS AIR SHUTTER VOLET DE L AIR OPEN 1 8 min 3 175mm CONTROL VALVE TYPE TYPE DE SOUPAPE Skytech AF 40004 VENTING VACUATION Existing 5 B Vent venting intake air 2 ply aluminum flexpipe...

Page 7: ...mply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est un appareil vent direct qui...

Page 8: ...re scale Press SET button to skip or advance to Fuel Type setup Press the UP or DOWN button to switch control from Natural to LP or LP to Natural Gas Press SET button to skip or advance to Clock setup...

Page 9: ...trol to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon wil...

Page 10: ...the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single...

Page 11: ...gasoline and other flammable liquids and vapors La zone appareil doit rester clair et exempt de mat riaux combustibles essence et autres vapeurs et liquides inflammables The flow of combustion and ve...

Page 12: ...toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the applia...

Page 13: ...tempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace an...

Page 14: ...provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifi et remplacez toute partie du sy...

Page 15: ...s components as this will damage the valve Ne pas communiquer 120 VAC la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance careful...

Page 16: ...OF UNIT B 1 TO INTERNAL SIDE COMBUSTIBLES 0 TO STANDOFFS C 15 TO BACK WALL FROM FRONT OF UNIT 0 TO STANDOFFS D 6 TO SIDE WALL E 32 5 FROM BOTTOM OF FIREPLACE TO BOTTOM OF STEEL STUD F 38 MINIMUM FROM...

Page 17: ...es du fournisseur de gaz Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la taille per...

Page 18: ...indiqu ci dessus pour r pondre aux codes d installation ou un cart de 5 de l air avec rev tement ambiance personnalis e The fireplace must be installed level and be attached to the framing with screw...

Page 19: ...ing system at test pressures equal to or less than 1 2 psi 3 45 kPa Cet appareil doit tre isol de l alimentation en gaz en fermant son robinet arr t pendant tout test de pression de la canalisation de...

Page 20: ...ow NOTE This fireplace is for replacement of B Vent units only using existing 5 certified B Venting and must terminate through the roof No side venting allowable 5 certified flexpipe and certified B v...

Page 21: ...certified flexpipe over the adaptor and 3 certified flexpipe Seal join with high temperature red silicon then secure to adaptor with 3 self tapping screws 9 Pull 3 certified flexpipe down over 3 colla...

Page 22: ...hat are in place 2 Align holes in the Restrictor that match the required degree of restriction 3 Fasten Restrictor Plate back in place DIRECT VENT TERMINATION TERMINATION CAP PART 1032 The above termi...

Page 23: ...rtified B Vent pipe 3 3 4 ROCK GLASS INSTALLATION ROCK VERRE D INSTALLATION Step 1 Sprinkle burner channel with glass Make sure to cover the burner pan evenly Then add decorative rocks to outer pan ar...

Page 24: ...amount of river glass to correct gas flow Transformez votre chemin e et attendez environ 10 15 minutes jusqu ce que les flammes sont une belle couleur jaune Notez la forme de la flamme et dans tous le...

Page 25: ...ook over the top of the door bracket and seal the door onto the fireplace Quand il est ferm correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la chemin e Rem...

Page 26: ...par un technicien sp cialis ou agr e Pour utilization uniquement avec les portes en verre certifies avec l appareil Ne pas utiliser de mat riaux de substitution Ne pas les portes en verre d abus par l...

Page 27: ...lot and main burner flames must be steady and not lifting off or floating The top 3 8 1 2 10 13mm of the thermocouple should be engulfed by the pilot flame 3 3 8 PRIMARY AIR ADJUSTMENT AJUSTEMENT DE L...

Page 28: ...orifice with a smaller size for installations over 4500 feet 1372m For the USA de rate the unit from sea level according to the gas installation code Toutes les vannes ont t pr programm es et certifi...

Page 29: ...ed to the box 3 3 11 GAS VALVE ACCESSIBILITY ACCESSIBILIT ROBINET DE GAZ CAUTION ATTENTION TURN THE MAIN GAS POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A...

Page 30: ...SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ To access the high limit safety thermostat for replacement Pour acc der au thermostat de s curit limite haute pour le remp...

Page 31: ...THEN NEED TO WAIT 12 15 MINUTES TO BE ABLE TO RESTART YOUR FIREPLACE FAN MUST BE SET TO MINIMUM FAN LEVEL 1 TO RESTART CE FOYER EST CON U POUR FONCTIONNER AVEC LE FAN ON MINIMUM NIVEAU DE FAN 1 SI LE...

Page 32: ...system should be annually inspected by a qualified agency Le syst me de ventilation devrait tre inspect s annuellement par une agence qualifi e 2 Visually check the burner and pilot flames occasional...

Page 33: ...fice or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighting instructions in Section 2 1 Un nettoyage p riodique est n cessaire pour un fonc...

Page 34: ...ne de gaz 7 Disconnect the thermostat or on off switch wires from the valve if applicable D branchez le thermostat ou marche arr t fils de l interrupteur de la vanne si applicable 8 Remove the gas lin...

Page 35: ...the burner line orifice or ports 2 Check and clean 3 Defective remote 1 Conduct a continuity test or jumper wire test and replace if defective check batteries 4 Defective wiring or connections 2 Condu...

Page 36: ...ss Rock Kit RGKBCF36 N A Thermostat Thermodisc 36T21 11795 CSA UL Intermittent Pilot Remote Control Valve Parts Description Part Pilot Assembly Intermittent PSE NA291 CSA UL Valve AF 40004 CSA C US Va...

Page 37: ...cian or contractor must have installed the gas fireplace Installation must be done in accordance with the installation instructions included with the product and all local and national building and fi...

Page 38: ...z Inca Metal de coupe est garanti d tre exempt de d fauts de mat riaux et de fabrication pour une p riode de 5 ans compter de la date d achat Cette garantie couvre chambres de combustion changeurs de...

Page 39: ...soires ou indirects Cette garantie d finit les obligations et la responsabilit de l Inca Metal Cutting l gard de l Inca Metal Cutting foyer au gaz et toute autre garantie expresse ou implicite l gard...

Page 40: ...Page 40 of 45 8 0 LABEL INFORMATION...

Page 41: ...remove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et do...

Page 42: ...Page 42 of 45 APPENDIX A AMERICAN FLAME VALVE INFORMATION...

Page 43: ...Page 43 of 45 APPENDIX A Continued...

Page 44: ...the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off This setting is generally used in cold climates to keep the firebox warm d The Continuous Pilot mode...

Page 45: ...Page 45 of 45 APPENDIX A Continued AF 4000 Wiring Diagram Inca Metal Cutting Ltd Unit 100 11091 Bridgeport Road Richmond BC V6X 1T3 Canada...

Reviews: