Sierra Flame BONAPARTE-36 Installation And Operating Instructions Manual Download Page 9

Page 9 of 44   

IMPORTANT 

PLEASE READ THE FOLLOWING CAREFULLY 

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises 

during the start up or cool down cycle.  

It is not unusual for gas fireplaces to give off some odors the first time they are burned. This is 

due to the oils and sealants in the manufacturing process. 

PLEASE ENSURE YOUR ROOM IS WELL VENTILATED DURING BURN OFF–OPEN ALL WINDOWS 

It is recommended that you burn your fireplace for at least 4 (four) hours the first time you use it.

  

IMPORTANT 

S'IL VOUS PLAÎT LIRE ATTENTIVEMENT CE QUI SUIT 

Il est normal pour les foyers fabriqués d'acier à dégager une certaine expansion et / ou des bruits 

de contraction pendant le démarrage ou cycle de refroidissement. 

Il n'est pas inhabituel pour les foyers à gaz de dégager certaines odeurs la première fois qu'ils 

sont brûlés. Cela est dû aux huiles et produits d'étanchéité dans le processus de fabrication. 

S'IL VOUS PLAÎT VOUS ASSURER pièce est bien aérée pendant BRÛLER - Ouvrir toutes les 

fenêtres 

Il est recommandé que vous brûlez votre foyer pendant au moins 4 (quatre) heures la première 

fois que vous l'utilisez. 

WARNING 

Hot while in operation. Do Not Touch. Severe burns may result. Keep children, clothing, 

furniture, gasoline and other liquids having flammable vapors away. 

  Toddlers, young children and others may be susceptible to accidental contact burns. A 

  physical barrier is recommended if there are at risk individuals in the house. To restrict 

  access to a fireplace or stove install an adjustable safety gate to keep toddlers , young 

  children and at risk individuals out of the room and away from hot surfaces. 

Any safety screen or guard removed for servicing an appliance must be replaced prior to 

operating the appliance. 

Installation and repair should be done by a qualified service person.  The appliance should 

be inspected before use and at least annually by a professional service person.  More 

frequent cleaning may be required due to excessive lint from carpeting, bedding material, et 

cetera.  It is imperative that control compartments, burners and circulating air passageways 

of the appliance be kept clean. 

AVERTISSEMENT 

L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures 

graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres 

liquides produisant des vapeur inflammables loin de l’appareil. 

Les tout-petits, les jeunes enfants et d'autres peuvent être sensibles aux brûlures par 

contact accidentel. Une barrière physique est recommandé s'il ya des personnes à risque 

dans la maison. Pour restreindre l'accès à une cheminée ou un poêle installer une barrière 

de sécurité réglable pour garder les tout-petits, les jeunes enfants et les personnes à risque 

de la salle et à l'écart des surfaces chaudes. 

Tout écran ou grille de protection pour l'entretien d'un appareil doit être remplacé avant de 

faire fonctionner l'appareil. 

Installation et réparation doit être effectuée par un technicien qualifié. L'appareil doit être 

inspecté avant son utilisation et au moins annuellement par un technicien qualifié. Un 

nettoyage plus fréquent peut être nécessaire en raison de peluches provenant des tapis, 

literie, etc. Il est impératif que les compartiments de contrôle, les brûleurs et les conduits 

d'air de l'appareil soient gardés propres.

 

 

Summary of Contents for BONAPARTE-36

Page 1: ...as supplier from a neighbour s phone Follow gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified install...

Page 2: ...ous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournis...

Page 3: ...rmostat Wall Switch or Digital On Off Remote 16 3 3 4 Direct Vent Information 16 22 3 3 5 Glass Rock Media Installation 23 3 3 6 Door Installation and Safety Screen 23 25 3 3 7 Initial Firing 26 3 3 8...

Page 4: ...s et intoxication au monoxyde de carbone DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZA...

Page 5: ...reil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuel...

Page 6: ...a GAS INLET SUPPLY PRESSURE ENTREE DE PRESSION Minimum 5 0 w c 1 2 kPa Minimum 7 0 w c 1 74 kPa Maximum 10 5 w c 2 61 kPa Maximum 13 0 w c 3 23 kPa ORIFICE SIZE 0 4500 FORMAT D ORIFICE 48 DMS 56 DMS A...

Page 7: ...nsed gas fitter Failure to comply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est...

Page 8: ...e de combustion Maintain adequate accessibility clearances for servicing and proper operation Respecter les distances minimales d accessibilit suffisante pour l entretien et bon This appliance shall n...

Page 9: ...toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the applia...

Page 10: ...y call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety...

Page 11: ...par un technician qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau INSTRUCTIONS D ALLUMAGE 1 ARR TEZ Lisez les instructions de s curit sur la por...

Page 12: ...witch operates Variable Speed Setting Turn the control to the desired setting When the knob is turned fully clockwise the fan will set to minimum speed Warning Electrical Grounding Instructions This a...

Page 13: ...s components as this will damage the valve Ne pas communiquer 120 VAC la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance careful...

Page 14: ...sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la taille permise manteau repose sur l l vation au dessus de la gar...

Page 15: ...ppliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or le...

Page 16: ...FORMATION The unit must be connected to listed 2 ply aluminium venting 4 flex vent on the exhaust side and listed 6 flex vent on the air intake side Install the vent components according to the manufa...

Page 17: ...ge Figure 4 This appliance s venting system is room sealed or Direct Vent This means that it does not require room air for combustion but draws air from outside the building USE OF COUPLERS WITH FLEX...

Page 18: ...al termination cap part 1393 Note 2 Ply Horizontal venting shall be supported by means of a steel strap every 3 Example Where A A Vertical 2 And B B Horizontal 5 EXAMPLES MINIMUM VERTICAL V1 V2 MAXIMU...

Page 19: ...llow above instructions for resealing venting when reconnecting to system FIGURE 6 VENT RESTRICTOR INSTALLATION VENT RESTRICTOR To fasten the Restrictor Plate to the ceiling of the firebox 1 Remove th...

Page 20: ...enter mark inside dimensions Cut and frame the exterior wall to accept the wall thimble Install the wall thimble on the inside of the exterior wall shield using wood screws Attach the venting to the t...

Page 21: ...t ceiling install a Box Wall thimble Cut a 9 square hole and frame as shown in the diagram below NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STAT...

Page 22: ...da 12 in 30 cm porch deck or balcony 0 0 3 3 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Ga...

Page 23: ...orte Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to corre...

Page 24: ...top of the door bracket and seal the door onto the fireplace Quand il est ferm correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la chemin e Removal is in re...

Page 25: ...s dans une goutte de silicone haute temp rature dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le panneau de verre de nouveau dans le cadre de la porte...

Page 26: ...arm up Parfois apr s un d marrage froid la vapeur peut se condenser et voiler le verre et les flammes peuvent tre partiellement bleu Apr s quelques minutes l humidit dispara t et les flammes deviendro...

Page 27: ...unit at higher elevations it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 4500 feet 1372m For the USA de rate the unit...

Page 28: ...ttom of the firebox before pulling the fan out through the gap on the right hand front of the unit Une fois que le ventilateur est d tach du mur retirez l aimant de l extr mit moteur du ventilateur Re...

Page 29: ...1 Remove the door as in 3 3 6 Enlevez la porte comme dans 3 3 6 2 Undo the thumb screws on the valve mount brackets at either end of the valve and slide valve out through access area below door Desse...

Page 30: ...E RECOMMAND 1 The venting system should be annually inspected by a qualified agency Le syst me de ventilation devrait tre inspect s annuellement par une agence qualifi e 2 Visually check the burner an...

Page 31: ...ce or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighting instructions in Section 2 1 Un nettoyage p riodique est n cessaire pour un foncti...

Page 32: ...la vanne de gaz 7 Disconnect the thermostat or on off switch wires from the valve if applicable D branchez le thermostat ou marche arr t fils de l interrupteur de la vanne si applicable 8 Remove the g...

Page 33: ...ay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple as shown in...

Page 34: ...anual for correct log placement V Flame burns blue and lifts off burner 1 Insufficient combustion air being supplied 1 Ensure that no foreign material blocks air inlets Ensure the vent is adequate 2 M...

Page 35: ...estrictor 2543 N A Door Glass Gasket 6AL N A Orifice NG MP0505 48 N A Orifice LP MP0505 56 N A Glass Kit BGK N A Fan GL43X188 UR Intermittent Pilot Remote Control Valve Parts Description Part Pilot As...

Page 36: ...extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in accordance with the installa...

Page 37: ...laim 7 0 GARANTIEDEPROTECTION Les produits Inca Metal Cutting sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s fiers de leur travail Le br leu...

Page 38: ...a discr tion se d charger de toutes les obligations relatives cette garantie en remboursant l acheteur original garanti le prix de gros de toutes les pi ces garanties mais d fectueuses Nonobstant les...

Page 39: ...Page 39 of 44 8 0 LABEL INFORMATION...

Page 40: ...remove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et do...

Page 41: ...Page 41 of 44 APPENDIX A AMERICAN FLAME VALVE INFORMATION Copper wire...

Page 42: ...Page 42 of 44 APPENDIX A Continued...

Page 43: ...is in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts o...

Page 44: ...Page 44 of 44 APPENDIX A Continued AF 4000 Wiring Diagram Inca Metal Cutting Ltd Unit 100 11091 Bridgeport Road Richmond BC V6X 1T3 Canada Brown...

Reviews: