8.0 LABEL INFORMATION (continued)

 

 

 

 Sections of the venting system have not been installed. 

WARNING

 

– Do not operate the appliance 

until all sections have been assembled and installed in accordance with the manufacturer’s 
instructions. 

Des sections du système d’évacuation n’ont pas été installées. 

AVERTISSEMENT

 - Ne pas utiliser 

l’appareil tant que toutes les sections n’ont pas été assemblées et installées selon les instructions du 
fabricant 

 
 

WARNING 

Electrical Grounding Instructions 

This  appliance  is  equipped  with  a  three  prong  (grounding)  plug  for  your  protection  against  shock                          
hazard and should be plugged directly into a properly grounded three prong receptacle.  Do not cut or       
remove the grounding prong from this plug. 

AVERTISSEMENT

 

Instructions à la terre électrique 

Cet appareil est équipé d'un à trois broches (terre) pour votre protection contre les risques de choc 

électrique et doit être branché directement dans une prise à trois broches récipient. Ne pas couper ou 

retirer la broche de terre de cette fiche. 

 

 

 

WARNING:

 Fire or explosion hazard. Can cause property damage, severe injury or death. 

This is a fast acting thermocouple. Replace it only with another fast-acting thermocouple specified by 
the appliance manufacturer. Refer to manual for the replacement part number. 

AVERTISSEMENT

 

: Risque d’incendie ou d’explosion. Peut entraîner des dommages matériels, des 

blessures graves ou la mort.  Ceci est un thermocouple rapide. Peut être remplacé uniquement par 
un autre thermocouple rapide spécifié par le fabricant de l’appareil. Veuillez consulter à la notice 
pour le numéro de pièce.  
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for BLST-LP

Page 1: ...tallation and service must be performed by a qualified installer service agency or gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF T...

Page 2: ...ion et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Une mauvaise installation de réglage la modification de services ou de maintenance peut causer des dommages corporels ou matériels Reportez vous à ce manuel Pour toute assistance ou information supplémentaire consulter un installateur qualifié un service ou le f...

Page 3: ...3 3 2 Gas Line Installation 22 3 3 3 Thermostat Wall Switch or Digital On Off Remote 22 24 3 3 4 Direct Vent Information 24 33 3 3 5 Glass Installation 34 3 3 6 Door Installation 35 3 3 7 Initial Firing 36 3 3 8 Manifold Pressure 36 3 3 9 Primary Air Adjustment 36 37 3 3 10 Altitude Adjustment 37 38 3 3 11 Fan Access 38 40 3 3 12 Gas Valve Access 40 41 4 0 MAINTENANCE 4 1 Maintenance Safety 42 4 2...

Page 4: ...ry or death from fire burns explosions electrical shock and carbon monoxide poisoning AVERTISSEMENT Lisez ce manuel attentivement et complètement avant d essayer de monter utiliser ou entretenir ce foyer Suire les instructions pour assurer une bonne installation Risque de dommages ou de blessures si l appareil n est pas installé selon les instructions du fabricant ou si des pièces autres que celle...

Page 5: ...r l entretien d un appareil doit être remplacé avant de faire fonctionner l appareil Installation et réparation doit être effectuée par un technicien qualifié L appareil doit être inspecté avant son utilisation et au moins annuellement par un technicien qualifié Un nettoyage plus fréquent peut être nécessaire en raison de peluches provenant des tapis literie etc Il est impératif que les compartime...

Page 6: ... ORIFICE 0 2000 SOUPANGE D ORIFICE 51 DMS 60 DIMS AIR SHUTTER VOLET DE L AIR OPEN 1 8 min 3 175mm FULLY OPEN CONTROL VALVE TYPE TYPE DE SOUPAPE Skytech AF 40004 Robertshaw Skytech AF 40004 Robertshaw VENTING ÉVACUATION 2 ply aluminum vent Selkirk Duravent Metal Fab ICC or Security Venting 2 ply aluminum vent Selkirk Duravent Metal Fab ICC or Security Venting FAN VENTILATEUR Variable Speed 115 Volt...

Page 7: ... Failure to comply will void the warranty This appliance has been certified for use with natural gas and propane This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est un appareil à évent direct qui attire tous l air de combustion provenant de l extérieur du bâtiment par une entrée d évent L installation doit se conformer aux codes locaux En l absence de codes locaux ...

Page 8: ...es will activate the setup mode Setup mode can also be activated by pressing the FLAME REAR and PROG TIME buttons simultaneously for 5 seconds The control will exit setup mode if no button is pressed for 20 seconds Appropriate icon on LCD will flash when ready for setup Press the UP or Down button in setup mode to change the temperature scale Press SET button to skip or advance to Fuel Type setup ...

Page 9: ...ntrol to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon will flash Press the UP or DOWN button to set the running time in 10 minute increments Press and release the SET button The timer will run for the set time duration Pressing the TIMER button while in Ti...

Page 10: ...e the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single audible beep will be heard Press the MODE button on the transmitter to learn the transmitter to the system A series of beeps will be heard Up to two additional NON THERMOSTATIC transmitters can be us...

Page 11: ...erving a separate solid fuel burning appliance Cet appareil ne doit pas être raccordé à une cheminée desservant un autre appareil brûlant des combustibles solides The appliance area must be kept clear and free from combustible materials gasoline and other flammable liquids and vapors La zone appareil doit rester clair et exempt de matériaux combustibles essence et autres vapeurs et liquides inflam...

Page 12: ...ers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be req...

Page 13: ...ttempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to the lowest setting 3 T...

Page 14: ...quer une explosion ou un incendie D N utilisez pas cet appareil s il a été plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l eau INSTRUCTIONS D ALLUMAGE 1 ARRÊTEZ Lisez les instructions de sécurité sur la portion supérieure de cette etiquette 2 Réglez le thermosta...

Page 15: ...n this label 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Controls are accessed by opening the bottom louver 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell...

Page 16: ...pez l alimentation électrique de l appareil 4 Les contrôles sont accessibles par l ouverture de la persienne inférieure 5 Poussez le bouton de contrôle du gaz et tourner vers la droite pour OFF 6 Attendez cinq 5 minutes pour laisser échapper tout le gaz Puis une odeur de gaz y compris près du plancher Si vous sentez une odeur de gaz ARRÊTEZ Suivez B des consignes de sécurité ci dessus sur cette ét...

Page 17: ...nding Instructions Instructions à la terre électrique This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Cet appareil est équipé d une broche de trois terre pour votre protection contre les risques d électrocution ...

Page 18: ...Page 18 of 60 Figure 2 ...

Page 19: ...t s components as this will damage the valve Ne pas communiquer 120 VAC à la valve de contrôle du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance carefully for any damaged or missing components specifically check the glass condition Report any problems to your dealer within 30 days of purchase 3 3 INSTALLATION For satisfactory results it is necess...

Page 20: ...S 40 TO INTERNAL CEILING COMBUSTIBLE MATERIAL 2 TO INTERNAL SIDE COMBUSTIBLES 6 TO EXTERNAL SIDE WALL 36 MINIMUM CEILING HEIGHT FROM TOP OF UNIT 40 MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE 12 DEEP SEE DIAGRAM NEXT PAGE 0 BOTTOM OF FIREPLACE TO FLOOR 26 5 FROM BOTTOM OF FIREPLACE TO CENTER OF TERMINAL VENT 32 FROM BOTTOM OF FIREPLACE TO BOTTOM OF 2 x4 FRAMING on edge 32 00 12 00 36 00 min Non com...

Page 21: ...iner la taille permise manteau repose sur l élévation au dessus de la garniture unités supérieures CAU TION ATTENTION When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant up to 250o F to prevent discolorations Lors de l utilisation de peinture ou de laque à la fin de la cheminée de peinture ou laque doit être résistante à la chaleur jusqu à 250o F pour prév...

Page 22: ...d arrêt doit être déconnectée de la canalisation de gaz pendant tout test de pression du système à des pressions supérieures à 1 2 psi 3 45 kPa Install the gas line as follows The appliance shall be installed with a manual shut off ball valve and additional pressure regulator to bring line pressure down to 14 w c Installez la conduite de gaz comme suit L appareil doit être installé avec une vanne ...

Page 23: ...ostat Soyez conscient que la longueur du câble augmente la probabilité de la tension de fonctionnement adéquat diminue TABLE 1 THERMOSTAT WIRE INFORMATION WIRE SIZE MAX WIRE LENGTH AWG mm ft m 22 0 6 10 3 0 20 0 8 25 7 6 18 1 0 40 12 2 16 1 3 64 19 5 14 1 6 100 30 5 2 After the unit is installed and the gas line hooked up crimp a fork connector to each wire and attach them to the TH TP and TH scre...

Page 24: ...e côté de l échappement et répertoriés 7 flex évent sur le côté d admission d air ou peut être utilisé avec sécurité ventilation Dura Vent 4 x 6 5 8 avec l utilisation d adaptateurs Dura Vent 0924N3 P574 partie les s Selkirk Direct Temp évacuation avec Dura Vent adaptateur partie 0924N3 CPI évacuation avec adaptateur partie TM 4AA2 ou Metal Fab évacuation directe à l utilisation de Metal Fab adapt...

Page 25: ...mum horizontal vent system consists of Dura Vent adapter Part 0924N3 45 off the unit 34 10363 mm vertical length off the 45 pipe 3 90 degree elbows 12 3658 mm maximum horizontal length Wall thimble part IMC1082A Dura Vent Horizontal termination cap 0984 or Selkirk Horizontal termination cap 4DT HC The maximum vertical system consists of Dura Vent adapter Part 0924N3 45 off the unit Up to 34 10363 ...

Page 26: ...t 0924N3 45 off the unit Up to 34 10363 mm of vertical length Fire stop Flashing Collar Termination cap part SV4CGV Use a ceiling fire stop when penetrating a ceiling or floor Use a wall thimble when penetrating an inside or outside wall Vent terminals shall not be recessed into a wall or siding Metal Fab Venting The minimum vent system for horizontal termination must consist of Metal Fab adapter ...

Page 27: ...tical length with 3 90 degree bends and a 12 3658 mm horizontal length measured to center of 45 vent pipe Wall thimble part IMC1082A Horizontal termination cap part IMC1070A or IMC1070B Note Horizontal strapping shall be supported by means of a steel strap every 3 Venting configuration straight out off 45 pipe Minimum 12 Maximum 24 Horizontal Vertical Venting Sample Chart Vertical Horizontal Venti...

Page 28: ...ound the outside of the male part of the vent A bead of silicone should be used on the outside of the joint after assembly to seal the supply air If the venting is disconnected for servicing be sure to follow above instructions for resealing venting when reconnecting to system FIGURE 7 H Max V V1 Min H H1 Max A 2 3 6 B 8 5 12 V V1 Min H H1 Max A 3 6 B 5 12 NOTE A minimum clearance to combustibles ...

Page 29: ...k off one side of the restrictor plate For 20 restriction break off both sides of the restrictor plate For 0 restriction do not install No restrictor 0 10 20 restrictor 10 18 40 restrictor 18 26 60 restrictor 26 34 NOTE ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD CAUSE POOR COMBUSTION AND OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE HAZARD PERMETTRE LA tuyau de ventilat...

Page 30: ...sheet metal screws then attach the 7 vent to the termination and fasten with 4 8 x hex head sheet metal screws be sure that the flex vent overlaps the termination collars a minimum of 2 Then attach the termination to the exterior wall using four wood screws through the holes in the corner of the vent terminal The next step is to apply a bead of mil pac or RTV 106 to top of the 4 exhaust collar on ...

Page 31: ...and frame as shown in the diagram below NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STATE PROVINCE TO PROVINCE TOUJOURS vérifier les codes locaux avant l installation VENTILATION ETC DÉGAGEMENTS peut varier d ÉTAT PROVINCE NOTE CONSULT DURAVENT PARTS LIST OR SIERRA FLAME S FIREPLACE MANUFACTURING PARTS LIST FOR PART NUMBERS FOYER Duravent CONS...

Page 32: ...of 2 from any wall To prevent water seepage install the flashing with upper portion under the roofing material and the lower portion over the roofing material Note Do not fasten down until the final adjustments to the vent have been made The diagram at right shows the minimum clearances as per the chart on page 32 3 00 12 00 ...

Page 33: ...rty M Clearance under veranda 12 in 30 cm porch deck or balcony 0 0 3 3 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if...

Page 34: ...de la porte Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to correct gas flow WARNING AVERTISSEMENT YOU MUST WEAR FLAME AND HEAT RESISTANT GLOVES FOR THESE ADJUSTMENTS VOUS PORTER DES GANTS DE FLAMME ET RESISTANT A LA CHALEUR DE CES AJUSTEMENTS CAU TION ATTEN...

Page 35: ...tement recommandé que vous contactez une personne qualifiée Retirez les morceaux n oubliez pas de porter des gants et enlever la porte Voir la liste des pièces de rechange à la fin du manuel vous aurez besoin d un 5 mm panneau de verre trempé avec joint installé Laïcs dans une goutte de silicone à haute température dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans l...

Page 36: ...ure will disappear and the flames will become yellow Visually check the flame after warm up 3 3 8 MANIFOLD PRESSURE REGULATOR ADJUSTMENT The manifold pressure regulator controls gas input and flame height and is pre adjusted at the factory No further adjustment is required PILOT FLAME ADJUSTMENT For proper operation the pilot and main burner flames must be steady and not lifting off or floating Th...

Page 37: ...ar la garantie d usine 3 3 10 ALTITUDE ADJUSTMENT Altitude Natural Gas Orifice Size Propane Orifice Size 0 2000 ft 0 610 m 44 56 2000 4000 ft 610 1219 m 45 57 4000 6000 ft 1219 1829 m 46 58 All valves have been pre set and certified for installation at elevations from 0 2000 feet 0 610m above sea level When installing this unit at higher elevations it is necessary to decrease the input rating by r...

Page 38: ...des mers Pour les États Unis de taux de l unité de niveau de la mer selon le code d installation de gaz 3 3 11 FAN ACCESSIBILITY FAN ACCESSIBILITÉ OPTIONAL CAUTION ATTENTION TURN THE MAIN GAS POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL...

Page 39: ...d installation et peut être retiré de la paroi latérale 4 Once removed from the wall the fan will slide out through the opening Une fois retiré du mur que les fan vont glisser par l ouverture 5 To replace fan and reassemble the fireplace go in reverse order from steps 4 through 1 Pour remplacer les fan et montons la cheminée aller dans l ordre inverse des étapes 4 à 1 ...

Page 40: ...CAUTION ATTENTION TURN THE MAIN GAS POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ 1 Remove the lower access panel Retirez le panneau d accès inférieur Lower Acc...

Page 41: ...ity Soigneusement incliner la valve à travers l ouverture et de sortir de la chambre de combustion pour l accessibilité 4 Replace valve in reverse order from steps 3 through 1 Remplacer la vanne dans l ordre inverse les étapes 3 à 1 WARNING AVERTISSEMENT BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL GAS CONNECTIONS AFTER REINSTALLATION OF VALVE IL EST INDISPENSABLE DE VÉRIFIER LES FUITES DE GAZ A TOUS ...

Page 42: ...ppliance regularly Annual service An annual service call should take between 1 2 hours Start by disassembling the unit take off the door and remove all the embers burner and logs Clean fan with a vacuum to remove any dust Vacuum the whole firebox and all the air passages Clean the burner After everything is clean check all the connections and the chassis ground and reassemble Clean the glass 4 3 G...

Page 43: ...ce and disconnect the gas line from the valve to the main orifice Débrancher la conduite de gaz à l appareil et débranchez la conduite de gaz de la vanne à l orifice principal 5 Remove the screws holding the valve bracket to the base of the unit and lift valve valve bracket out Retirez les vis de fixation du support de la valve à la base de l unité et de levée de soupape et support de la valve à 6...

Page 44: ... depress control knob II Pilot will not stay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple 2 Defective thermocouple 2 Replace thermocouple 3 Thermocouple not installed properly 3 Make sure all wire connections at the gas valve terminals are tight and the therm...

Page 45: ...the millivolt meter The pilot flame may not be high enough for the flame to properly engulf the thermopile If so adjust and reset If voltage is still insufficient replace thermopile 9 Wall switch thermostat or wires are defective 9 Follow previous corrective action check switch and wiring Replace where defective IV Soot deposits on glass 1 Air inlet blocked or restricted 1 Clean air inlets 2 Vent ...

Page 46: ...Pilot will not stay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple as shown in Figure 27 2 Defective thermocouple 2 Replace thermocouple 3 Thermocouple not installed properly 3 Make sure all wire connections at the gas valve terminals are tight and the thermoco...

Page 47: ...placement V Flame burns blue and lifts off burner 1 Insufficient combustion air being supplied 1 Ensure that no foreign material blocks air inlets Ensure the vent is adequate 2 Manifold pressure set too high 2 Check manifold pressure 3 Vent system restricted 3 Check vent system VI Main flame does not burn properly 1 Incorrect vent or termination used 1 Confirm venting termination are those which a...

Page 48: ... CSA Rock Glass Kit RGKST21 N A Intermittent Pilot Remote Control Valve Parts Description Part Pilot Assembly Intermittent PSE NA291 CSA UL Valve AF 40004 CSA C US Valve with step motor installed AF 4044 CSA C US Remote Step Motor for AF 4000 Valve AF 4000MOT CSA C US Supreme Control Module incl wire harness AF 4000MOD S01 CSA C US Plug in Adapter 7 5V A C 24 wires AF 4000ADP24 CSA C US Battery Ba...

Page 49: ...y not be extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alter...

Page 50: ...ieure assemblés par des artisans qualifiés qui sont fiers de leur travail Le brûleur et la valve sont des essais d étanchéité et d essai ont tiré sur un poste de contrôle de qualité Une fois assemblé chaque foyer est soigneusement inspecté par un technicien qualifié avant l emballage afin de s assurer que vous le client reçevez un produit de qualité que vous attendez de Sierra Flame GARANTIE DU FO...

Page 51: ...s à l égard de cette garantie en remboursant à l acheteur d origine le prix de gros de toute pièce garantie qui est défectueuse s Nonobstant toutes dispositions contenues dans la présente garantie la responsabilité de Sierra Flame en vertu de cette garantie est définie comme ci dessus et il ne doit en aucun cas s étendre à des dommages indirects accessoires ou indirects Cette garantie définit les ...

Page 52: ...Page 52 of 60 8 0 LABEL INFORMATION NATURAL GAS ...

Page 53: ...Page 53 of 60 8 0 LABEL INFORMATION PROPANE ...

Page 54: ... the grounding prong from this plug AVERTISSEMENT Instructions à la terre électrique Cet appareil est équipé d un à trois broches terre pour votre protection contre les risques de choc électrique et doit être branché directement dans une prise à trois broches récipient Ne pas couper ou retirer la broche de terre de cette fiche WARNING Fire or explosion hazard Can cause property damage severe injur...

Page 55: ...Page 55 of 60 APPENDIX A AMERICAN FLAME VALVE INFORMATION ...

Page 56: ...Page 56 of 60 APPENDIX A Continued ...

Page 57: ... in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off This setting is generally used in cold climates to keep the firebox warm d The Continuous Pilot mode can also be activated by an optional hand held remote control 2 Remote Control Feature The AF 4000 ...

Page 58: ...r propane Each unit leaves the factory equipped for one specific fuel but it is simple to field convert the unit to an alternate fuel The original type of fuel is marked on the ratings label of the manual Les modèles Palisade sont conçus pour brûler du gaz naturel ou au propane Chaque unité quitte l usine équipée pour un combustible spécifique mais il est simple de convertir aligner l appareil à u...

Page 59: ...f prior to disconnecting the electrical power before proceeding with the conversion ATTENTION l alimentation en gaz doit être coupée avant de débrancher l alimentation électrique avant de procéder à la conversion 2 Remove the door rock glass kit tray and burner Retirez les portes céramique ou rock kit de verre plateau journal et le brûleur 3 Change the burner pilot orifices with the orifice suppli...

Page 60: ..._____________________________________________________ with the conversion kit NGCKBL21ST or LPCKBL21ST by the above named qualified service ageny technician which accepts the responsibility that the conversion has been completed properly as per instructions in this manual Cet appareil a été converti sur DATE _______________________________________ partir de NG LP pour LP NG PAR____________________...