![Siemens TC12 Installation, Commissioning And Maintenance Handbook Download Page 27](http://html.mh-extra.com/html/siemens/tc12/tc12_installation-commissioning-and-maintenance-handbook_374544027.webp)
TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000
Page 17
Issue 10
Set the I/O Port addresses of the boards using DIP switch 1 (DS1) positions 9 to
11, as shown below:
Board SW9 SW10 SW11 Address
1 ON
OFF
OFF
0x100
2 ON ON OFF
0x120
3 OFF
OFF ON 0x200
4 ON
OFF ON 0x220
Set the interrupts using DIP switch 2 (DS2), positions 1 to 8, as shown below:
Board SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Interrupt
1
OFF OFF ON OFF OFF OFF OFF OFF IRQ5
2
OFF OFF OFF OFF OFF ON
OFF
OFF
IRQ11
3
OFF OFF OFF OFF OFF OFF OFF ON IRQ15
4
OFF OFF OFF ON OFF OFF OFF OFF IRQ7
2.2.2.8.2 DIGI AccelePort 16e
The DIGI PC/16i comprises a full length ISA card (DIGI part number 60000200)
and an IMD Distribution Unit (labelled Digi AccelePort 16e ISA DB25M RS232).
The PC board has a single jumper (J1) and 2 DIP switches (DS1 and DS2).
The jumper is used to set the local program memory size, which should be 64K.
The jumper has 3 pins which are numbered from left to right. The jumper should
be set so that pins 2 and 3 are bridged.
The setting of the2 DIP switches, DS1 and DS2, is the same as for the DIGI
PC/16i board (See 2.2.2.8.1).
2.2.2.8.3 DIGI AccelePort Xem
The DIGI AccelePort Xem comprises a three quarter length Xem ISA Host Adapter
(419/4/95931/000 - DIGI part number 77000211), a 16em DB25 Module
(653/4/05229/000 - DIGI part number 76000073) and a Xem 5ft Cable
(707/4/08514/000 - DIGI part number 62080060). Each 16em DB25 Module is
supplied with a short cable which enables a maximum of 4 16em DB25 Modules to
be daisy chained together. Two 16em DB25 Modules may be powered from the
ISA Host Adapter. Additional Modules require auxiliary power supplies
(605/4/08678/000 - DIGI part number 76000321).
The PC must be powered off before the Xem host adapter card is installed. The
PC should remain off until the 16em DB25 Modules have been connected to the
host adapter. The only set up required on the Xem host adapter is to set the I/O
port address to 124H-127H using DIP switch DS1
Address SW1 SW2 SW3 SW4
124H-127H
OFF ON ON ON