Siemens SR35iA series Configuration Manual Download Page 9

3   Configuration

3.2.1

SR35iA Aperio Controller setup

To configure the Aperio™ in Bewator Entro - proceed as follows:

1. Start the Bewator Entro

Installer

program and log on with

Username

and

Password

.

2. In the

Controller

- select the

Aperio

tab.

3. The system discovers the Aperio hubs that are connected to the system.

These are displayed as **CnHxx. Otherwise new hubs have to be manually

created with name and address.

4. Mark the hub and click

Edit

. You can also right-click and choose

New

,

Edit

or

Delete

.

5. Rename the hub to a suitable name and check the address.

6. All other settings are done referring to the ordinary Bewator Entro manuals.

3.2.2

Bewator Entro card parameters

As the Omnis system uses 16 digits in the card number, the Bewator Entro system

must be configured for this.

Proceed like this:

1. Start the Bewator Entro

Installer

program and log on with

Username

and

Password

.

2. Select on the menu

System > System settings

.

3. Click the

Card reader parameters

tab.

4. Click on

Custom

and enter

Start position

as 1 and

Number of digits

as 16.

5. Click

OK

and close the dialog box.

3.2.3

Configure doors

When the Aperio hubs are connected the doors can be renamed and setup referring to

the ordinary Bewator Entro manuals.

You see new doors as ** CnHyyAxxx, where yy is the address of the hub that the door

/ lock is paired with, and xxx is the address that the lock has been allocated in the PAP

software, called for the "EAC address".

Besides the EAC address each Aperio locks has an ID that is six characters long, this

is found on both the lock and in the PAP software.

Both the lock's EAC address and its ID is displayed in the Bewator Entro software.

NOTE!

If an existing Aperio™ lock is replaced, the basic addressing must be performed
again with the PAP software. And the new Aperio address must be applied manu-
ally in the Door properties of the Bewator Entro program.

9

Siemens AB

2015-05-05

Security Products

Summary of Contents for SR35iA series

Page 1: ...Access Control SR35iA Aperio Controller Configuration Manual MP1 Siemens AB Security Products ...

Page 2: ...ubject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100162 1 ...

Page 3: ... 4 System overview 6 2 5 Wirings 7 3 Configuration 8 3 1 Aperio configuration 8 3 2 Bewator Entro configuration 8 3 2 1 SR35iA Aperio Controller setup 9 3 2 2 Bewator Entro card parameters 9 3 2 3 Configure doors 9 3 3 Omnis configuration 10 3 3 1 Omnis special notes when using Aperio doors 10 3 3 2 Omnis functions not supported with Aperio 11 ...

Page 4: ...d together with ASSA ABLOY Aperio door solutions and the Omnis Security system More information can be obtained from the separate reference manuals supplied with each of the systems l ASSA ABLOY Aperio l Bewator Entro l Omnis Different information might be useful dependent of which system you are familiar with 4 Siemens AB 2015 05 05 Security Products ...

Page 5: ...s applies when using the Aperio together with Bewator Entro and Omnis Maximum number of Aperio hubs per SR35iA Aperio Controller 15 hubs Maximum number of Aperio readers doors per Aperio hub 8 readers doors Recommended by ASSA is 4 Maximum number of doors per SR35iA Aperio Controller regardless of number of hubs SR35iA 8 SR35iA 16 SR35iA 32 8 16 32 Maximum RS485 cable length 1200 m Maximum distanc...

Page 6: ...ault This means that a command to unlock or lock the door may become effective a time between 0 60 minutes Version 3 With this version of the Aperio lock it will contact the hub at least every ten seconds Any commands for unlocking or locking will take effect much quicker 2 4 System overview Following picture shows the system layers Note that three different system concept co operate Omnis Bewator...

Page 7: ...cial wiring is the RS485 cabling between the SR35iA Aperio Controller and the Aperio hubs Each SR35iA Aperio Controller can connect to maximum 15 hubs on the RS485 bus Note that the RS485 bus must be terminated in each end and this is done by setting a DIP switch in the actual hub 7 Siemens AB 2015 05 05 Security Products ...

Page 8: ... Entro and Omnis Note 2 Maximum number of Access group Personal doors must not exceed six 6 3 1 Aperio configuration All setup have to be done according to the original Aperio documentation and using the Aperio PAP Configuration tool The addressing of the hubs is done via DIP switches The hubs communicates via RS485 to Bewator Entro and wireless to the locks 3 2 Bewator Entro configuration The SR3...

Page 9: ... on with Username and Password 2 Select on the menu System System settings 3 Click the Card reader parameters tab 4 Click on Custom and enter Start position as 1 and Number of digits as 16 5 Click OK and close the dialog box 3 2 3 Configure doors When the Aperio hubs are connected the doors can be renamed and setup referring to the ordinary Bewator Entro manuals You see new doors as CnHyyAxxx wher...

Page 10: ...orm in Omnis is 8 and for Bewator Entro it is 6 If user enters 8 Access groups Personal door the last two is not entered into Bewator Entro and will not work Maximum number of Access group Personal door is 6 for Omnis with Aperio Access Group The Access group is created and edited in Bewator Entro which door to access and when Shown in Omnis as name and not possible to edit In Omnis it is possible...

Page 11: ... Aperio readers in Omnis Graphics Not possible for graphic status indication of Aperio doors Alarm control Not possible to have Aperio readers in alarm zones Anti passback Not possible to have global anti passback with Aperio door Personal code No personal code instead of cards can be used 11 Siemens AB 2015 05 05 Security Products ...

Page 12: ...rnational Headquarter Englundavägen 7 SE 171 24 Solna Tel 46 8 629 0300 www siemens com securityproducts 2015 Copyright by Siemens AB Data and design subject to change without notice Supply subject to availability Document Nr A 100162 1 Edition Date 2015 05 05 ...

Reviews: