3 Configuration
3.2.1
SR35iA Aperio Controller setup
To configure the Aperio™ in Bewator Entro - proceed as follows:
1. Start the Bewator Entro
Installer
program and log on with
Username
and
Password
.
2. In the
Controller
- select the
Aperio
tab.
3. The system discovers the Aperio hubs that are connected to the system.
These are displayed as **CnHxx. Otherwise new hubs have to be manually
created with name and address.
4. Mark the hub and click
Edit
. You can also right-click and choose
New
,
Edit
or
Delete
.
5. Rename the hub to a suitable name and check the address.
6. All other settings are done referring to the ordinary Bewator Entro manuals.
3.2.2
Bewator Entro card parameters
As the Omnis system uses 16 digits in the card number, the Bewator Entro system
must be configured for this.
Proceed like this:
1. Start the Bewator Entro
Installer
program and log on with
Username
and
Password
.
2. Select on the menu
System > System settings
.
3. Click the
Card reader parameters
tab.
4. Click on
Custom
and enter
Start position
as 1 and
Number of digits
as 16.
5. Click
OK
and close the dialog box.
3.2.3
Configure doors
When the Aperio hubs are connected the doors can be renamed and setup referring to
the ordinary Bewator Entro manuals.
You see new doors as ** CnHyyAxxx, where yy is the address of the hub that the door
/ lock is paired with, and xxx is the address that the lock has been allocated in the PAP
software, called for the "EAC address".
Besides the EAC address each Aperio locks has an ID that is six characters long, this
is found on both the lock and in the PAP software.
Both the lock's EAC address and its ID is displayed in the Bewator Entro software.
NOTE!
If an existing Aperio™ lock is replaced, the basic addressing must be performed
again with the PAP software. And the new Aperio address must be applied manu-
ally in the Door properties of the Bewator Entro program.
9
Siemens AB
2015-05-05
Security Products