3 Configuration
3
Configuration
The setup of an environment consisting of the three different system components
Aperio™, Bewator Entro and Omnis should be made in three separate sessions:
1. Mount the Aperio™ components (hubs and door locks) and configure these
according to the Aperio™ documentation.
2. Configure the Bewator Entro software according the section
Bewator Entro
configuration
[
➙
8] in this manual plus the ordinary Bewator Entro documentation.
3. Configure the Omnis BAPSI communication using the Omnis documentation.
Note 1
The
number of digits
in the card must be aligned and same in both Bewator
Entro and Omnis.
Note 2
Maximum number of Access group/Personal doors must not exceed six (6).
3.1
Aperio™ configuration
All setup have to be done according to the original Aperio™ documentation and using
the Aperio™ PAP Configuration tool.
The addressing of the hubs is done via DIP switches.
The hubs communicates via RS485 to Bewator Entro and wireless to the locks.
3.2
Bewator Entro configuration
The SR35iA Aperio Controller is designed to only manage Aperio™ door
environments.
Technically the SR35iA Aperio Controller communicates with the Aperio™ hubs via
the ASSA-ABLOY Device protocol (wired to the Local RS485 Communication
terminal). See "Wirings" on page 7.
The software configuration is done in the PC where the Bewator Entro installation
software is installed.
8
Siemens AB
2015-05-05
Security Products