Application planning
4.4 Overload protection
RN-S SA
24
Operating Instructions, 09/2016, A5E32605810A-03
If the transverse force is so great that it exceeds the restoring force of the pendulum bolt
(and thus the deflection limit), then corresponding protective measures are required.
Pendulum limiters or guide elements are suitable for this, for example.
Pendulum limiters must be constructed or set in such a way that the maximum deflection
cannot be exceeded in any direction. This is shown in two examples in the following figure.
Figure 4-2
Pendulum limitation with a maximum deflection of 4 mm as exemplified by two weighing
platforms
Pendulum limiters are integrated in the RN-S SA compact installation units.