Description
3.2 Design and function
RN-S SA
Operating Instructions, 09/2016, A5E32605810A-03
17
In the next step, lower the load bearing by loosening the top hexagon nuts. The top plate is
lowered onto the pendulum support. The weight is now on the load cells.
NOTICE
Loosening the hexagon nuts
Loosen the hexagon nuts in turn in small steps.
Note:
•
The compact installation units are screwed tight to the brackets.
•
By loosening a hexagon nut, the weight of the bearing implement is distributed among
the other hexagon nuts and is partially increased.
Avoid overloading individual hexagon nuts.
Figure 3-5
Operating state
In this state, the load cells with the pressure pieces form self-centering units. The compact
installation units allow the top plates and the load bearing implement to be deflected to the
side. The countersunk head screws provide lifting protection and, to a limited extent,
pendulum limitation.
Figure 3-6
Compact installation unit with load cell and grounding cable