![Siemens SIWAREX WL230 BB-S SA Operating Instructions Manual Download Page 59](http://html.mh-extra.com/html/siemens/siwarex-wl230-bb-s-sa/siwarex-wl230-bb-s-sa_operating-instructions-manual_374535059.webp)
9.1.10
SIWAREX WL230 SB-S CA
Table 9-10
Technical data SIWAREX WL230 SB-S CA
Variable
Value
Type series
WL230
Designation
SB-S CA
Construction type
Shear beam
Possible applications
Platform scales,
overhead rail scales,
container scales,
conveyor scales
Rated load E
max
100; 250; 500 kg
1; 2; 3; 5; 10 t
Accuracy class according to OIML R60
C3; C4; C5
Max. scale interval n
LC
3000; 4000; 5000
Min. scale interval V
min
For E
max
= 100; 250; 500 kg; 1; 2 t
For E
max
= 3; 5; 10 t
E
max
/ 10000; 15000; 20000
E
max
/ 10000; 15000; 18000
Combined error F
comb
± 0.015% C
n
Creep error F
cr
30 min
± 0.015% C
n
Temperature coefficient
Characteristic value T
Kc
Zero signal T
Ko
0.03 % C
n
/ 10 K
0.03 % C
n
/ 10 K
Min. initial loading E
min
0 kg
Maximum working load L
u
150 % E
max
Break load L
d
300 % E
max
Maximum lateral load L
lq
100% E
max
Rated measuring path h
n
For E
max
= 100 kg:
For E
max
= 250 kg:
For E
max
= 500 kg:
For E
max
= 1 t:
For E
max
= 2 t:
For E
max
= 3 t:
For E
max
= 5 t:
For E
max
= 10 t:
0.17 mm
0.15 mm
0.32 mm
0.63 mm
1.2 mm
0.9 mm
0.6 mm
0.8 mm
Recommended supply voltage
5 to 12 V DC
Rated characteristic value C
Rated
3.0 ± 0.003 mV/V
1)
Tolerance of zero signal D
o
< ± 1.0% C
n
Input resistance R
i
350 ± 3.5 Ω
Output resistance R
o
350 ± 3.5 Ω
Insulation resistance R
is
5000 MΩ at 50 V DC
Rated temperature range B
tn
-10 to +40 °C
Technical data
9.1 Functional data
SIWAREX WL200
Operating Instructions, 12/2021, A5E02199611B-13
59