SITRANS P310 with HART
40
A5E35075329-01, 05/2015
Certificates and approvals
HART
Designation
II 2/3 G Ex nA IIC T4/T5/T6 Gc
II 2/3 G Ex ic IIC T4/T5/T6 Gc
Connection "nA"
U
n
= 45 V
Connection "ic"
To a circuit with the operating values:
U
i
= 45 V
Effective inner capacitance
C
i
= 6 nF
Effective inner inductance
L
i
= 0.4 mH
•
Explosion protection in accordance
with FM
Certificate of Compliance 3008490
Designation (XP/DIP) or IS; NI; S CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia
IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
Permissible ambient temperature T
amb
= T4: -40 ... +85 °C (-40 ... +185 °F)
T
amb
= T5: -40 ... +70 °C (-40 ... +158 °F)
T
amb
= T6: -40 ... +60 °C (-40 ... +140 °F)
•
Explosion protection as per CSA
Certificate of Compliance 1153651
Designation (XP/DIP) or (IS)
CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4 ... T6:
CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
Permissible ambient temperature T
amb
= T4: -40 ... +85 °C (-40 ... +185 °F)
T
amb
= T5: -40 ... +70 °C (-40 ... +158 °F)
T
amb
= T6: -40 ... +60 °C (-40 ... +140 °F)
A
Appendix
A.1
Certificate
The certificates can be found on the enclosed CD and on the Internet under:
Certificates (
http://www.siemens.com/processinstrumentation/certificates
A.2
Technical support
Technical Support
If this documentation does not provide complete answers to any technical questions you may have, contact Technical
Support at:
●
Support request (
http://www.siemens.com/automation/support-request
●
More information about our Technical Support is available at
Technical support (
http://www.siemens.com/automation/csi/service
Internet Service & Support
In addition to our documentation, Siemens provides a comprehensive support solution at:
●
Service&Support (
http://www.siemens.com/automation/service&support
) where you will find support news, support
documents including EDDs and software, and also support from experts.