65
PBD-51041059
SITRANS LG260 - Operating Instructions
44284-EN-171021
Ʋ
Cable: ø 6 mm (0.236 in) - PA coated 8 Nm (5.9 lbf ft)
Ʋ
Cable: ø 6 mm (0.236 in)
20 Nm (14.75 lbf ft)
Ʋ
Cable: ø 11 mm (0.433 in) - PA coated 20 Nm (14.75 lbf ft)
Ʋ
Rod: ø 16 mm (0.63 in)
20 Nm (14.75 lbf ft)
Torque for NPT cable glands and Conduit tubes
Ʋ
Plastic housing
max. 10 Nm (7.376 lbf ft)
Ʋ
Aluminium/Stainless steel housing
max. 50 Nm (36.88 lbf ft)
Input variable
Measured variable
Level of solids
Min. dielectric constant of the medium
ε
r
≥ 1.5
Output variable
Output
Ʋ
Physical layer
Digital output signal according to standard EIA-485
Ʋ Bus specifications
Modbus Application Protocol V1.1b3, Modbus over se-
rial line V1.02
Ʋ
Data protocols
Modbus RTU, Modbus ASCII, Levelmaster
Max. transmission rate
57.6 Kbit/s
Accuracy (according to DIN EN 60770-1)
Process reference conditions according to DIN EN 61298-1
Ʋ
Temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ
Relative humidity
45 … 75 %
Ʋ
Air pressure
+860 … +1060 mbar/+86 … +106 kPa
(+12.5 … +15.4 psig)
Mounting, reference conditions
Ʋ
Min. distance to internal installations > 500 mm (19.69 in)
Ʋ
Vessel
metallic, ø 1 m (3.281 ft), centric mounting, process fit
-
ting flush with the vessel ceiling
Ʋ Reflector
metallic, ø 1 m
Ʋ
Medium
Bulk solids - cereals, flour, cement (dielectric con
-
stant ~2.0)
Ʋ
Mounting
Probe end does not touch the vessel bottom
Sensor parameter adjustment
No gating out of false signals carried out