27
SFIDK.PS.022.Q5.02
-
Additional information
Order code
Please add „-Z“ to order No. and following
add-on code(s) with plain text
Verification FUE380
Verification certificate 2 x 3 points.
D10
Max. flow 50 ... 250 m
3
/h, depending on dimension
Verification certificate 2 x 3 points.
D11
Max. flow 250 ... 1300 m
3
/h, depending on dimension
Verification certificate 2 x 3 points.
D12
Max. flow 1400 ... 4200 m
3
/h, depending on dimension
Accredited Siemens calibration FUE380
Accredited Siemens ISO/IEC 17025 calibration.
D20
Max. flow 50 ... 250 m
3
/h, depending on dimension
(DN 50...200)
Accredited Siemens ISO/IEC 17025 calibration.
D21
Max. flow 250 ... 1300 m
3
/h, depending on dimension
(DN 100...500)
Accredited Siemens ISO/IEC 17025 calibration.
D22
Max. flow 1400 ... 4200 m
3
/h, depending on dimension
(DN 300...1200)
Material certificate
EN 10204-3.1
F10
Tag name plate
Stainless steel tag with 12 mm characters,
max. 15 characters (add plain text)
Y17
Self-adhesive plastic tag with 8 mm characters,
max. 15 characters (add plain text)
Y18
MLFB Ordering example
Customer requires a flowmeter for custody transfer:
DN 250, PN 25, compact version (media temperature max. 120 °C),
battery version.
Type approved according to EN 1434, verified and sealed for
Germany.
Material certificate and metal tag name plate
Pulse output for energymeter SITRANS FUE950
Ordering:
FUE380: 7ME3410-2LD05-4DG2-Z, F10,Y17
Example of appropriate energy meter:
Energy meter type:
FUE950-03110-0R1CB-10300-DK2-00012
Order-No.
Order code
Flowmeter SITRANS FUE380
7ME 3 4 1 0 -
(type approved)
-
Country / approved type
6)
Neutral, no approval mark
A
Denmark, EN 1434/OIML R75
E
Finland, EN 1434/OIML R75
F
Germany, EN 1434 (PTB approved)
G
Russia, EN 1434/OIML R75
M
Ukraine, EN 1434/OIML R75
P
China
Z
Q0C
MID-Approval (EN 1434/OIML R75), English
R
MID-Approval (EN 1434/OIML R75), German
S
MID-Approval (EN 1434/OIML R75), Polish
T
MID-Approval (EN 1434/OIML R75), French
U
Pulse width setup
5 ms (standard)
2
10 ms
3
20 ms
4
50 ms
5
100 ms
6
200 ms
7
500 ms
8
1)
Pipe material red brass
2)
EN 1434 flow values
3)
OIML R75 flow values
4)
PN 40 standard for DN 50...80 red brass pipes
5)
Lithium batteries are subject to special transportation regulations
according to United nations "Regulation of Dangerous Goods, UN 3090
and UN 3091". Special transport documentation is required to observe
these regulations. This may influence both transport time and costs.
4)
Other countries in progress
Please use online PIA Selector to get latest updates.
Product selector link:
www.pia-selector.automation.siemens.com