17
SFIDK.PS.022.Q5.02
After fitting new batteries, reset the internal power calculation counter to correctly indicate the
power capacity.
When new batteries are installed, the flowmeter startup routine begins. First, the display shows
the active software version. Then the message „reset.bat“ will appear. Press the key within six
seconds to reset the internal counter. When the internal counter is reset the battery symbol will
indicate „full“.
Press the key within 6 seconds. The message „accept“ will appear, the internal counter will be
reset, and the battery indicator will show „full“ - see Fig. 1.
The transmitter control panel is designed with a single key and a digital display for optimal dialog
- see Fig. 2 and Fig 3.
Key
Activate the key to toggle to the next index and related information - see Fig.2.
Operation
6
6.1
Flowmeter operation via key and display
8-digit display
Infra-red communication port
Single push button
Fig. 1
Fig. 2
Fig. 3